Sanitary Type Electromagnetic Flow Meter Smart Water Flow Meter GXEFM2000

Brand Name:Kacise
Certification:certificate of explosion-proof, CE
Model Number:GXEFM2000
Minimum Order Quantity:1pcs
Delivery Time:5-8 work days
Payment Terms:L/C, D/A, T/T, D/P, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

Kacise sanitary type smart process connection electromagnetic flowmeter insertion electromagnetic flow meter

Description


GXEFM2000 electromagnetic flow meters are intended for fluid measurement in most industries including water, wastewater, food and beverage, pharmaceutical and chemical.

There are two basic components of electromagnetic flow meter:

1) The Detector, which includes the flow tube, isolating liner and measuring electrodes, and

2) The Converter, which is the electronic device responsible for signal processing, flow calculation, display and output signals.

The materials of construction of the wetted parts( liner and electrodes) should be appropriate for the specification on the intended type of service. Revise of the compatibilities consistent with the shipment of each meter.


Technical Data


Measuring system


Measuring principleFaraday’s law
Application rangeElectrically conductive fluids
Measured Value
Primary measured valueFlow velocity
Secondary measured valueVolume flow

Design


FeaturesFully welded maintenance-free sensor
Flange version with full bore flow tube
Standard as well as higher pressure ratings
Large diameter range from DN15~3000 with rugged liners approved for drinking water
Industry specific insertion lengths
Modular constructionThe measurement system consists of a flow Sensor and a signal converter. It is available as compact and as separate version
Compact versionWith 511B converter: 110~240Vac Power
With 521B converter: 18~36V DC Power
With W800L/W800W: Battery Power
Remote version

In wall mount version with 211B converter

(110~240Vac or 221B converter 18~36V DC

With W800F converter: Battery Power
Measurement range-12…+12m/s /-40...+40ft/s

Measuring accuracy


Reference conditionsFlow conditions similar to EN 29104
Medium: water
Electrical conductivity: ≥300μs/cm
Temperature: +10~+30℃/+50~+80℉

Inlet setion: ≥5DN
Operating pressure: 1Bar/14.5psig
Flow Meter AccuracyStandard: 0.5% of rate
Optional: 0.2% of rate

Operating conditions


Temperature
Process temperatureHard rubber liner: -5~+60℃
Polypropylene liner: -5~+90℃
PTEF liner: -5~+120℃
Ambient temperatureStandard (with aluminum converter housing)

-20~+60℃ (Protect electrics against self-heating

with ambient temperature above 55℃

Stroage temperature-20~70℃
Pressure
EN 1092-1DN2200~3000: PN2.5
DN1200~2000: PN6
DN200~1000: PN10
DN65~150: PN16
DN10~50: PN40
Other pressure on request
ISO insertion lengthOptional for DN15~600
ASME B16.51~24”: 150lb RF
Other pressure on request
JISDN10~1000/ 2~40”: 10K
Other pressure on request
Pressure dropNegligible

Fluid
Physical conditionConductive liquids
Electrical conductivity≥5μs/cm
Permissible gas content (volume)≤5%
Permissible solid content≤70%

Installation conditions


InstallationTake care that flow sensor is always fully filled
For detailed information see chapter “Cautions for installation”
Flow directionForward and reverse
Arrow on flow sensor indicates positive flow direction
Inlet run≥5 DN
Outlet run≥2 DN

Process connection


Flange
EN1092-1DN25~3000 in PN6~40
ASME1~120” in 150 lb RF
JIS25~1000 in 10~20k
Design of gasket surfaceRF
Other sizes or pressure ratings on request

Ordering information


Model Suffix Code Description
GXEFM3000-1200-Com-4mA-Hart-DC-Pt-Teflon1-GR-D1400-Exd IIC T6 Gb 
Diameter-XXXX         Four Digitals: for example:0010: 10mm: 0015:15mm 0100: 100mm 1000: 1000mm
Transmitter-Com        Compact type
-Rem        Remote type
-Bat        Battery power supply type
-PRO        process control type
Signal Outpt-N       No output
-4mA       4-20mA
-Pul       1~5KHz pulse
-4Pul       4~20mA / 1~5KHz
Communication-N      No communication
-Hart      HART
-MOD      MODBUS-RTU
-PRO      PROFIBUS
-GPRS      GPRS net
-CDMA      CDMA net
-WHRT      Wireless HART
-Other      special order
Power Supply-AC     85V~250Vac@46~63Hz
nominal 20W
-DC     20~36VDC nominal 20W
-Bat     Battery power supply
-Bat+     Battery +12Vdc dual power supply
Other     special request
Electorde Material-316L    Stainless steel 316L
-HasB    Hastelloy B
-HasC    Hastelloy C276
-Pt    Platinum
-Ta    Tantalum
-Ti    Titanium
-WC    wolfram carbide
Liner material-Rub1   Neoprene(-20-60℃)
-Rub2   Neoprene(-20-90℃)
-Tef1   polytetrafluroethylene(-30-120℃)
-Tef2   polytetrafluroethylene(-20-160℃)
-P   Polyurethane
-FVMQ   FVMQ
-PFA   DFA
-ETFE   Ethylene tetraflurorethylene
Grounding Ring-N  No grounding ring
-GR  Grounding ring
-GE  Grounding Electrode
Wet part Connection attribute-DXX DXX: D06, D10, D16, D25,D40 D06: DIN PN6:
D10: DIN PIN10D16: DIN PN16; D25: DIN PN25 D40: DIN PN40 etc
-AX AX: A1, A3, A6 A1: ANSI 150#; A3: ANSI 300# A6: ANSI 600#
-JX JX: J1, J2, J3 J1: JIS10K;
J2: JIS 20K; J3: JIS 30K
-WF Wafer connection (available for DN2.5; DN6 flow meter) Body material: stainless steel
-TR Tri-Clamp for sanitary type (Body material: stainless steel)
Explosive-proof grade-Exd IIC T6 GbExd IIC T6 Gb
-Ndon't need

GXEFM2000 Series Electromagnetic Flow Meter

China Sanitary Type Electromagnetic Flow Meter Smart Water Flow Meter GXEFM2000 supplier

Sanitary Type Electromagnetic Flow Meter Smart Water Flow Meter GXEFM2000

Inquiry Cart 0