Battery Powered Water Sewage Flow Meter Electromagnetic Type Flow Meter

Brand Name:Kacise
Certification:certificate of explosion-proof, CE
Model Number:GXEFM2000
Minimum Order Quantity:1pcs
Delivery Time:5-8 work days
Payment Terms:L/C, D/A, T/T, D/P, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

High quality low price battery powered water sewage flow meter electromagnetic flowmeter


Description


GXEFM2000 electromagnetic flow meters are intended for fluid measurement in most industries including water, wastewater, food and beverage, pharmaceutical and chemical.

There are two basic components of electromagnetic flow meter:

1) The Detector,which includes the flow tube, isolating liner and measuring electrodes

2) The Converter, which is the electronic device responsible for signal processing, flow calculation, display and output signals.

The materials of construction of the wetted parts( liner and electrodes) should be appropriate for the specification on the intended type of service. Revise of the compatibilities consistent with the shipment of each meter.


Parameters


Pipe diameterDN6~DN2600
Accuracy0.3% (Option), 0.5%, 1.0% of F.S..
RepeatabilityBelow 0.25%
PowerAC: 220V, 50-60Hz; DC: +24V(Option)
Output Signals4~20mA, Pulse, 0~5V
Conduit connectionM20 * 1.5 Thread
Communication InterfaceRS-232; RS-485; HART
Operation Pressure1.0MPa, 1.6MPa, 4.0MPa, 16MPa (Special)
Fluid Temperature-20°C~80°C, 80°C ~130°C, 130°C ~180°C Depending on Lining Material
Ambient TemperatureSensor -40°C ~80°C. transducer -15°C ~50°C
Ambient Humidity≤ 85%RH (at 20C)
Cable Outlet SizeM20×1.5
Power Supply220VAC±10%, 50-60Hz±1Hz, 24VDC±10%, Battery power (3-5years)
Power Consumption≤ 15W
Protection RatingsRemote type: sensor IP68, transducer IP65.
MaterialsElectrode316L (stainless steel), Hastelloy C, Hastelloy B,Titanium, Tantalum, etc.
LinerPTFE, Soft rubb er, Hard rubber, F46, FS, PUR.
Measuring tubeSS 304, carbon steel
FlangeCarbon Steal, SS304
Ground ring316L (stainless steel), HC, Ti, Ta, Cu.
Connection of Flange

National Standard GB9119-88 (DIN2051, BS4504), JIS,ANSI. Screw.

Tri-clamp for sanitary application

Insertion type.

EX-proof protectionExde ib ii BT2
Quality control

ISO9001-2008, CE



Ordering information


Model Suffix Code Description
GXEFM3000-1200-Com-4mA-Hart-DC-Pt-Teflon1-GR-D1400-Exd IIC T6 Gb 
Diameter-XXXX         Four Digitals: for example:0010: 10mm: 0015:15mm 0100: 100mm 1000: 1000mm
Transmitter-Com        Compact type
-Rem        Remote type
-Bat        Battery power supply type
-PRO        process control type
Signal Outpt-N       No output
-4mA       4-20mA
-Pul       1~5KHz pulse
-4Pul       4~20mA / 1~5KHz
Communication-N      No communication
-Hart      HART
-MOD      MODBUS-RTU
-PRO      PROFIBUS
-GPRS      GPRS net
-CDMA      CDMA net
-WHRT      Wireless HART
-Other      special order
Power Supply-AC     85V~250Vac@46~63Hz
nominal 20W
-DC     20~36VDC nominal 20W
-Bat     Battery power supply
-Bat+     Battery +12Vdc dual power supply
Other     special request
Electorde Material-316L    Stainless steel 316L
-HasB    Hastelloy B
-HasC    Hastelloy C276
-Pt    Platinum
-Ta    Tantalum
-Ti    Titanium
-WC    wolfram carbide
Liner material-Rub1   Neoprene(-20-60℃)
-Rub2   Neoprene(-20-90℃)
-Tef1   polytetrafluroethylene(-30-120℃)
-Tef2   polytetrafluroethylene(-20-160℃)
-P   Polyurethane
-FVMQ   FVMQ
-PFA   DFA
-ETFE   Ethylene tetraflurorethylene
Grounding Ring-N  No grounding ring
-GR  Grounding ring
-GE  Grounding Electrode
Wet part Connection attribute-DXX DXX: D06, D10, D16, D25,D40 D06: DIN PN6:
D10: DIN PIN10D16: DIN PN16; D25: DIN PN25 D40: DIN PN40 etc
-AX AX: A1, A3, A6 A1: ANSI 150#; A3: ANSI 300# A6: ANSI 600#
-JX JX: J1, J2, J3 J1: JIS10K;
J2: JIS 20K; J3: JIS 30K
-WF Wafer connection (available for DN2.5; DN6 flow meter) Body material: stainless steel
-TR Tri-Clamp for sanitary type (Body material: stainless steel)
Explosive-proof grade-Exd IIC T6 GbExd IIC T6 Gb
-Ndon't need

Company Information

Xi'an Kacise is certified by ISO 9001-2008, GJB 9001B-2009, CE, intrinsic safety explosion-proof and isolated safety explosion-proof, etc. which assure our products are conform to the international standards.

We have been specializing in manufacturing pressure, level and flow measuring instruments and related products for 10 years. We have experienced technical and management personnel, through the efforts of our entire staff, we have become a professional measuring instrument manufacturer and solution provider. And we are continuously trying to improve product quality.

Currently, Kacise sensor is already exported to America, Spain, Australia, Chile and 20 other countries and regions, and received many favorable feedbacks. Our overseas distributers are also increasing. We regards “reasonable prices, efficient production time and good after-sales service” as our tenet, and hope to cooperate with more customers for mutual development.




China Battery Powered Water Sewage Flow Meter Electromagnetic Type Flow Meter supplier

Battery Powered Water Sewage Flow Meter Electromagnetic Type Flow Meter

Inquiry Cart 0