230×185×120mm Water Quality Sensor For Aquaculture Industrial

Brand Name:kacise
Certification:CE,FDA
Model Number:KBU601
Minimum Order Quantity:0-100
Delivery Time:10-15 days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

KFDO900 Do Meter Stainless Steel Sensor Water Quality For Aquaculture Industrial
Product Introduction

dissolved oxygen measuring instrument is based on fluorescence quenching principle.The fluorescent material at the front of the sensor is a special platinum porphyrin compound with a polyester foil that allows gas molecules to pass through. The surface is coated with a black light-blocking material to avoid interference by sunlight and other fluorescent substances in the water.
When blue light hits the fluorescent material, the fluorescent material is excited and emits red light. Since oxygen molecules can carry away energy (quenching effect), the time and intensity of the excited red light are inversely proportional to the concentration of oxygen molecules.By measuring the phase difference between the excitation red light and the reference light and comparing with the internal calibration value, the concentration of oxygen molecules can be calculated.After linearization and temperature compensation, the final value is output.


The advantage of fluorescence dissolved oxygen

In general, the fluorescence dissolved oxygen instrument can measure the oxygen content of water without flow rate, which is more accurate without the need for magnetic stirring machine.Although the first purchase cost is high, the electrode is very easy to use. It is usually replaced every 2-3 years, unlike the polarographic method, which requires electrode replacement, and the cost is very expensive.

Performance characteristics:

● Innovative fluorescence principle, no need to replace the diaphragm and electrolyte, basic maintenance free;
● No need to replace the fluorescent cap, lower use cost;
● No oxygen consumption, no flow rate and agitation requirements;
● will not be "toxic" because of sulfide, to overcome environmental interference;
● Free from cross interference of H2S, PH, CO2, NH3, SO4, CL-, CL2, etc.
● Higher resolution and measurement accuracy;
● The service life of the sensor is up to 5 years;

Apply:
Surface water, industrial sewage and municipal sewage

Q&A
What is zero drift?
It refers to the size of the indicating value of the automatic analyzer changing within a certain period of time when the zero correction liquid specified in this technical requirement is used as the sample for continuous testing.

What is Range drift?
refers to the change of the indicating value of the automatic analyzer in a certain period of time when the range correction liquid specified in this technical requirement is used as the sample for continuous testing.

What is Mean fail-free?
continuous running time refers to the ratio of the total running time (h) of the automatic analyzer to the number of failures (times) during the test period, which is shown in "MTBF". The unit is h/time.

What is response time (T90)?
electrodes from range correction fluid to zero correction fluid, the determination of displayed value range correction liquid concentration 90%.



Technical Parameters of Fluorescence Dissolved Oxygen Analyzer

ClassPerformanceParameter
TransmitterSize230×185×120mm
Weight1.5kg
Storage Temperature-40-60℃
Temperature-20-60℃ Avoid direct sunlight
Relative humidity5%~85% (no condensation)
Supply220VAC±10%,50Hz
Analog output4~20mA output or 0~20mA output (dissolved oxygen value or saturation), loop load maximum 750 ohms;Optional temperature 4~20mA output
The relay outputs3 relays with A capacity of 220 VAC/ 2 A. The outputs can be set for alarm or timing functions
Protective gradepolycarbonate enclosure, IP65
Field displayLCD display with backlit
Digital interfaceRS232 or RS485 interface, Modbus protocol can be supported.
SensorMeasurement rangedissolved oxygen: 0.00~20.00mg/ L or 0.00~20.00 PPM air saturation: 0~200%
Resolution0.01mg/L
The measurement accuracy±1%FS or ±0.15mg/L with the largest value
Repeatability≤0.2mg/L
Response timeless than 60 seconds
Temperature sensorWorking range: 0~60°C;Resolution: 0.01°C Accuracy: ±0.5°C;Response time: less than 10 seconds
Storage temperature-20°C ~60°C
Ambient temperature-20°C ~60°C
Medium temperature0℃~50℃
Maximum mounting depth10 m
Chemically adaptationmethanol and ethanol are safe to avoid other organic solvents
CalibratationAnoxic water and air were used for calibration respectively.It has been calibrated before leaving the factory, and generally there is no need to calibrate.
Anti-interferenseIt is not subject to cross interference of H2S, PH, CO2, NH3, SO4, CL-, CL2, CLO2, MeOH, EtOH, and various other ions.
FoilPolyester embedded with platinum porphyrin fluorescence
Light-proof coatingteflon
Foil lifeup to 5 years (10 second measurement interval)
Sensor shell size45 x 100 Φ
Weight1.2 kg
Cable standard10 meters
Sensor shellstainless steel


Ordering Information selection table



Ordering Information selection table
KFDO900Fluorescence Dissolved Oxygen Meter
Power supply
DC24V
AC220V
Cable length
10m
15m
20m
30m
Signal output
Only 4-20mA
Only 485

Also with 4-20mA , 485 signal output


Special custom signal
KFDO900-AC220V10mOnly 485

with AC220V adapter, cable between host and sensor,The cable length is 10 meters, the sensor is equipped without temperature compensation, and is equipped with only 485 communication signal output.





Contact us


Website: www.kacise.com
Phone: +86-17719566736
Email: sales@kacise.com
Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China

































































China 230×185×120mm Water Quality Sensor For Aquaculture Industrial supplier

230×185×120mm Water Quality Sensor For Aquaculture Industrial

Inquiry Cart 0