KNA500 Nitrate Ion Analyzer PVC Sensor For Fishery Industry
Product Introduction
Nitrate ion analyzer mainly uses ion selective electrode measurement method to achieve accurate detection
Of. The electrode has an ion selective membrane that reacts with the corresponding ion in the sample under test. The membrane is
An ion exchanger, which reacts with the ionic charge to change the membrane potential, can detect the liquid, like
The electric potential between this and the membrane. The difference between the two potentials detected on both sides of the membrane will generate an electric current
The test electrode, the reference electrode liquid forms the "loop" on one side, the membrane, the internal electrode liquid, and the internal electrode on the other
Edge.
The difference in ion concentration between the internal electrode liquid and the sample will produce electrochemical reactions on both sides of the membrane of the working electrode
The voltage is directed to the amplifier through a highly conductive internal electrode, as is the reference electrode
To the location of the amplifier. Determination is obtained by detecting an exact standard solution with a known ion concentration
To measure the ion concentration in the sample.
Occurs in the aquifer of the ion-selective electrode substrate when the measured ion contacts the electrode in solution
Ion migration. The charge change of the migrating ion has an electric potential, which causes the potential between membrane surfaces to arise
Produces a potential difference between the measuring electrode and the reference electrode.
Areas of use include food, drinking water, agriculture and so on.
Nitrate Analyzer KNA500 Sensor
Nitrate analyzer KNA500 host
Nitrate Analyzer KNA500 Parameter Table
Performance | parameter |
Measuring range | 0.1-3.000mg/L (extensible), temperature 0-50℃ |
slope | 57±2 mv/p NO3 - ions |
response time | 30s(in 62mg/L NO3 solution) |
stability | ±0.3mv(30 min),±1mv(24h) |
Interference ions | CL/NO3=100 NO2/NO3=10 generates an error of 10% in the above proportion |
PH | 3-10 |
temperature | 0 to 40 ℃ |
Internal resistance | <1Mohm |
Pressure range | 0.3 Mpa or less |
Sensitive film | Organic ion exchange membrane, in a special solvent, and evenly distributed in PVC |
Shell material | Grey plastic |
size | 100mm long, 12mm diameter (other specifications can be customized) |
Ordering Information selection table
Ordering Information selection table | ||
KNA500 | Nitrate analyzer | |
Power supply | DC24V | |
AC220V | ||
Cable length | 5m | |
10m | ||
15m | ||
20m | ||
Temperature compensation | Sensor without temperature compensation | |
Sensor with temperature compensation | ||
Signal output | Only 4-20mA | |
Only 485 | ||
Also with 4-20mA , 485 signal output | ||
Special custom signal | ||
KNA500-DC24V-5m-Sensor without temperature compensation-Only 485 | Nitrate analyzer host, with DC24V adapter, cable between host and sensor,The cable length is 5 meters, the sensor is equipped without temperature compensation, and is only 485 communication. |
Contact us
Website: www.kacise.com
Phone: +86-17719566736
Email: sales@kacise.com
Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi
Province, China
Abbreviations table
NTU
The unit of turbidity is "degree", which is equivalent to the
degree of turbidity produced by 1L water containing 1mg SiO2 (or
white clay, diatomite), which is 1 degree, or Jackson.Turbidity
unit is JTU, 1JTU=1mg/L white clay suspension.
The turbidity shown by modern instruments is the unit of scattering
turbidity NTU, also known as TU.1NTU= 1JTU.
Recently, it is considered internationally that the standard of
turbidity prepared with ullotropin-hydrazine sulfate has good
reproducibility and is chosen as the uniform standard of
FTU.1FTU=1JTU.