Add to Cart
KCS540 Infrared CO2 Module
KCS540 is a gas detection module based on the principle of NDIR infrared absorption, which is suitable for detecting the concentration of carbon dioxide in a gaseous environment at room temperature.
KCS540 adopts a patented optical cavity, imported light source and dual-channel detector to achieve dual optical path reference compensation in space. KCS540 has good selectivity, no oxygen dependence and long life.
KCS540 has UART, IEC digital output, analog voltage output and PWM frequency output mode, which is convenient for customers to choose the application; The KCS540 provides zero calibration, sensitivity calibration, and clean air calibration commands, and provides customers with a manually calibrated MCDL pin to facilitate the relative zero calibration of the sensor module using outdoor free-flowing clean air. KCS540 adopts diffusion ventilation method, which has a fast diffusion speed.
KCS540 can be widely used in HVAC fresh air control, indoor air quality monitoring, agricultural and animal husbandry production process monitoring, can be installed in intelligent buildings, ventilation systems, robots, automobiles and other applications. It can also be applied to other confined spaces for air quality monitoring.
KCS540 diffusion exterior view
KCS540 pump suction exterior view
parameter | symbol | minimum | Typical values | maximum | unit | |
Storage temperature | Tstg | -20 | - | 80 | °C | |
Operating temperature | TA | -20 | 60 | °C | ||
Operating humidity | HA | 0 | 90 | % RH | ||
Work pressure | PA | 0.8 | 1.2 | atm | ||
Supply voltage | Vs | 9 | 12 | 18 | V | |
Maximum operating current | Imax | 100 | 120 | 150 | mA | |
Detection range | 200 | 50000 | 100% vol can be customized | ppm | ||
Measurement accuracy | - | ± 50ppm or ±3% true value | ± 300ppm± 3% true | ppm | ||
T90 | diffusion | - | 30 | 60 | second | |
Repeatability | zero | <±50 | ppm | |||
50% FS | - | <± 2% of the measured value | - | |||
Life Span | 3 | 10 | 15 | year |
Unit: mm
Diffusion
Pump-suction type
The sensor is mounted with a positioning hole spacing of 44.5mand a mounting hole diameter of 2.8 mm
The wiring socket spacing is 2.54 m m
Note: SW400PV3.01, mounting aperture: 3.2mm
The sensor should be calibrated regularly, it is recommended that it be no more than 3 months, and calibration is not required on the long-term operation side if automatic calibration is turned on
Do not use the sensor for a long time in an environment with a high density of dust
Please use the sensor within the range of the sensor's power supply
3) Sensor measurement accuracy such as SW400, 0-2000pp
Order information sheet | |||||
KCS540 | KCS540 CO2 concentration sensor | ||||
xxxx | The sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm. | ||||
2000 | Range 200ppm (default). | ||||
10000 | Range 10000ppm | ||||
50000 | Range 50000ppm | ||||
encode | The reaction speed is divided into two types: fast and slow | ||||
S | Slow (default). | ||||
Q | fast | ||||
encode | Baud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering. | ||||
Custom | Confirm the baud rate before ordering | ||||
2400 | 2400bps baud rate | ||||
9600 | 9600bps baud rate | ||||
19200 | 19200bps baud rate | ||||
38400 | 38400bps baud rate (default) | ||||
encode | Serial port protocol | ||||
Modbus-RTU | Standard Modbus-RTU protocol (default). | ||||
Modbus-ASCII | Standard Modbus-ASCII protocol | ||||
Modbus-Self | Modbus private protocol | ||||
KCS540 | -2000 | -S | -38400 | -Modbus-RTU |
URL: www.kacise.com
Tel: +86-29-17719566736
Email: sales@kacise.com
Address: Tangyan South Road, Xi'an City, Shaanxi Province, China
Appendix
Shorthand | Full name |
VOL | 1% VOL refers to 1% of the volume of a particular gas in air. |
PPM | 1PPM means that the volume of a specific gas in the air accounts for one millionth. |
O2 | Oxygen molecules |
LCD | LCD display |
RS485 | Asynchronous serial port 485 |
DC | direct current |
AC | Communication |
PVC | polyvinyl chloride |