Pipe network flowmeter based on Doppler sensor

Pipe network flow meter is mainly used for hydrological parameter monitoring of sewage pipe network and rainwater pipe network, and it is not convenient for solar energy and mains power supply, and data need to be transmitted to the cloud platform. The host of the pipe network provides large capacity battery, DTU and low power management circuit.

Characteristic

(1)Support flow rate, instantaneous flow,cumulative flow,Liquid level, temperature

(2)Water quality parameters can be customized

(3)The collection and reporting time can be adjusted

(4)Continuous work for more than 2 years

(5)Installation and construction are small

(6)Multi-channel sensor connectivity

(7)Disposable high capacity battery

1.Description of products

The product measures the flow rate according to the principle of ultrasonic Doppler effect, and can measure the water level and temperature through the pressure sensor. The shell adopts PVC plastic, which can effectively waterproof and seal.


◆ Modbus communication protocol and RS485 bus are used to communicate with the handheld computer.

◆ The underwater sensor device is easy to install. With metal base fixed device, easy installation.

◆ All the equipment adopts electronic design, wide voltage power supply, low power consumption, no mechanical parts. It has the advantages of accurate measurement and stability, high reliability and strong anti-interference.

◆ A wide range of applications. It can be applied in various water environments from pure water to Yellow River water.


2.Principle of the product

Doppler flowmeter principle: When the ultrasonic source and the observer do relative motion, the frequency received by the observer will be different from the frequency of the ultrasonic source. Therefore, the small particles and bubbles moving with water relative to the ultrasonic transducer will also change the receiving frequency of the transducer, and increase with the increase of the motion speed of the suspension in the water. Thus, the Doppler frequency shift is measured, and the flow speed of the water at the point of the Doppler current meter is measured. This is multiplied by the cross-sectional area of the channel to obtain the flow information.

Because Doppler flow measurement uses the speed of sound propagation in the water, and the speed of sound propagation in the water is closely related to the water temperature, the device has a built-in temperature sensor for temperature measurement, and then correct the sound speed.

The level depth measurement uses a pressure sensor to measure the distance between the position of the flow velocity sensor and the liquid level.


3.Product Parameter

3.1 Products Attributes

◆ Measurement types: point velocity, liquid level, temperature, flow rate

◆ Protection class: IP68

◆ Measuring method: online

◆ Measurement principle: acoustic Doppler method, velocity area method

◆ Power supply: battery, solar energy, mains power

◆ Output signal: Modbus RS485

◆ Output signal content: point velocity, instantaneous flow, cumulative flow, water level, temperature

◆ Output signal (external power supply) : 4~20mA

◆ 4~20mA Output signal content: instantaneous flow

◆ Liquid pH requirements: pH 6~8

◆ Liquid pressure requirement: 1 standard atmosphere under natural environment

◆ Continuous operating power consumption:12V*65mA=12V*0.065A≈0.8W

3.2 Measurement Index

measured variableParameterPrecision

Flow velocity range

(m/s)

0.021m/s~6.00m/s

(~12m/s customizable)

±1.0%±1cm/s

Water temperature measurement range

(℃)

-10℃~60℃±1(℃)
Liquid level measurement range(m)

0.05m~10m

(~100m customizable)

0.5%±0.5cm
Instantaneous flow range1l/s~99.99m³/s
cumulative flow0.1m³~999999m³

3.3 Specifications

contentParametercondition
working voltage(V)7.2V~24VDC
power consumption(mA)≤65mA(Moment of launch)12V power supply
operating depth(m)0.1m~10m

Data update cycle

(s)

6s~60s