Add to Cart
Turbine flow meter for measuring the flow of clean liquids
Introduction
The Turbine Flow Meter is an excellent device designed for
measuring the flow of clean liquids. It operates based on advanced
turbine technology, which ensures high accuracy and reliability in
flow measurement. With its simple yet effective design, it can be
easily installed and maintained. It converts the liquid flow into
electrical signals, allowing for convenient data acquisition and
monitoring. This meter is widely used in various industries, such
as chemical, pharmaceutical, and food, providing accurate and
stable performance. It is an ideal choice for those who need
precise liquid flow measurement, helping to optimize production
processes and ensure product quality.
Dimensions
Thread Connection
Flange Connection
Pipe Size DN (mm) | Sensor Dimension (mm) | Flange Dimension (mm) | thread size | ||||||
L | H | D | D1 | D2 | D3 | n-do | L1(mm) | G | |
4 | 225 | 145 | 1/2 | ||||||
6 | 225 | 145 | 1/2 | ||||||
10 | 345 | 170 | 1/2 | ||||||
15 | 75 | 190 | 95 | 65 | 45 | 4-14 | 23 | 1 | |
20 | 85 | 210 | 105 | 75 | 55 | 4-14 | 23 | 1 | |
25 | 100 | 230 | 115 | 85 | 65 | 4-14 | 30 | 11/4 | |
32 | 120 | 250 | 140/135 | 100 | 78 | 4-18 | 30 | 11/4 | |
40 | 140 | 260 | 150/145 | 110 | 85 | 4-18 | 35 | 2 | |
50 | 150 | 270 | 165/160 | 125 | 100 | 4-18 | |||
65 | 150 | 290 | 185/180 | 145 | 125 | 4-18 | |||
80 | 200 | 300 | 200/195 | 160 | 135 | 8-18 | |||
100 | 220 | 330 | 220/215 | 180 | 155 | 8-18 | |||
125 | 250 | 380 | 250/245 | 210 | 185 | 8-18 | |||
150 | 300 | 390 | 285/280 | 240 | 210 | 8-23 | |||
200 | 360 | 455 | 340/335 | 295 | 265 | 12-23 | |||
250 | 400 | 510 | 405 | 355 | 320 | 12-26/25 | |||
300 | 420 | 565 | 460 | 410 | 375 | 12-26/25 | |||
400 | 560 | 680 | 580 | 525 | 485 | 16-30 | |||
500 | 600 | 790 | 715/705 | 650 | 608 | 20-34 |
Technical Specifications
Pipe Size (DN)mm | Flow Range(m3/h) | Nominal pressure (Mpa) | ||
0.2% | 0.5% | 1.0% | ||
4 | 0.04-0.25 | 6.3 | ||
6 | 0.1-0.6 | 6.3 | ||
10 | 0.2-1.2 | 6.3 | ||
15 | 1.2~4 | 0.6~6 | 0.4~6 | 2.5 6.3 16 |
20 | 2~6 | 0.8~8 | 0.6~8 | |
25 | 3~10 | 1.2~12 | 1.2~12 | |
32 | 4~12 | 1.5~15 | 1~20 | |
40 | 8~25 | 3~30 | 3~30 | |
50 | 12~40 | 5~50 | 5~50 | 6.3 2.5 |
65 | 15~60 | 7~70 | 5~70 | |
80 | 20~100 | 16~100 | 12~120 | |
100 | 50~160 | 25~160 | 20~200 | |
125 | 50~200 | 30~250 | 25~280 | |
150 | 100~300 | 50~300 | 40~400 | |
200 | 200~600 | 100~600 | 80~800 | |
250 | 300~1000 | 160~1000 | 120~1200 | 2.5 |
300 | 250~1600 | |||
400 | 400~2500 | |||
500 | 600~4000 |
Ambient Temperature | -20~+55℃ |
Relative Temperature | 5%~95% |
Atmospheric Pressure | 86~106Kpa |
Ordinary Type Medium Temperature | -20~+120℃ |
Explosion-Proof Type Medium Temperature | -20~70℃ |
Explosion Proof | dⅡBT5 |
Power Supply | Two wire: +24VDC Three wire:+12VDC~+24VDC |
Connection | Thread or Flange |