Add to Cart
CL2-B1/CL2-B1+ Chlorine Sensor
The CL2-B1 sensor is a PPM sensor that is designed for a broad variety of applications and instrumentation including portable gas detectors and fixed gas detection systems for industrial safety, environmental air quality and process control. This product is available in our standard format (CL2-B1) and with our patented Integrated Smart Technology (CL2-B1+) that has an IST board with a memory chip and temperature sensor integrated in the sensor. The + sensors store specific calibration, specification, and identification data on every sensor allowing plug and play operation. The on-board temperature sensor improves the accuracy and simplicity of temperature compensation algorithms.
Sensor Data
Performance | Sensitivity Response time Zero current Resolution Range Linearity Overgas limit | nA/ppm in 10ppm Cl2 t90 (s) from zero to 10ppm Cl2 (33Ω load resistor) ppm equivalent in zero air RMS noise (ppm equivalent) (33Ω load resistor) ppm limit of performance warranty ppm error at full scale, linear at zero and 10ppm Cl2 maximum ppm for stable response to gas pulse | -600 to -1150 < 60 ± 0.4 < 0.02 20 < ± 0.2 60 |
Lifetime | Zero drift Sensitivity drift Operating life | ppm equivalent change/year in lab air % change/year in lab air, monthly test months until 80% original signal (24-month warranted) | < 0.03 < 6 > 24 |
Environmental | Sensitivity @ -20°C Sensitivity @ 50°C Zero @ -20°C Zero @ 50° | % (output @ -20°C/output @ 20°C) @ 10ppm % (output @ 50°C/output @ 20°C) @ 10ppm ppm equivalent change from 20°C ppm equivalent change from 20°C | 70 to 90 90 to 105 < 0 to 0.1 < 0 to -1 |
Cross Sensitivity | H2S sensitivity NO2 sensitivity NO sensitivity SO2 sensitivity CO sensitivity H2 sensitivity C2H4 sensitivity NH3 sensitivity CO2 sensitivity | % measured gas @ 20ppm H2S % measured gas @ 10ppm NO2 % measured gas @ 50ppm NO % measured gas @ 20ppm SO2 % measured gas @ 400ppm CO % measured gas @ 400ppm H2 % measured gas @ 400ppm C2H4 % measured gas @ 20ppm NH3 % measured gas @ 5% (Vol) CO2 | < -300 < 120 < 1 < -1 < 0.1 < 0.1 < 0.1 < 0.1 0 |
Key Specifications | Temperature range Pressure range Humidity range Storage period Load resistor Weight | °C kPa % rh continuous (see note below) months @ 3 to 20°C (stored in sealed pot) Ω (for optimum performance) g | -20 to 50 80 to 120 15 to 90 6 33 < 13 |
Interface | Communication Bus Max. Bus Speed Input Logic Levels Absolute Max. Input Signal | Compatible with the 400 kHz I²C protocol Up to 1 MHz High (Recessive) < 2.3 V | Low (Dominant) < 0.2 V 3.6 V |
Electrical | Supply Voltage Range Supply current – Stand-By Supply current – Operating Power Supply Conditioning ESD Protection Bus Pins Input Capacitance | 1.7 V to 3.6 V < 5 μA < 0.15 mA (temperature reading only) < 2.15 mA (temperature reading + memory reading/writing) Built-In 100 nF decoupling capacitor 4 kV (human body model) - Enhanced ESD / Latch-Up protection 15 pF max. |
Performance | Operational Temperature Temperature Sensor Accuracy Memory Data Retention Memory Write Cycles | –40 °C to +85 °C ±1°C (-0°C to +70°C) > 200 years > 4,000,000 |
Data & Communication | Memory IC & I2C Address Temperature IC & I2C Address Product Data Start Address Calibration Data Start Address User Data Area CRC Polynomial Digital Signature Algorithm | M24128X-FCU | Device Address: R - 0xA0 / W – 0xA1 MAX31875R0TZS+T | Device Address: R - 0x90 / W – 0x91 0x0900 0x0B00 0x0D00 – 0x18FF (3,072 Bytes) 0x 01 04C1 1DB7 SHA-256 |