Add to Cart
4KW 380V VSD Variable Speed Drive is applied to CNC machine tools
1, Load feature
CNC machine is a mechanical-electrical integrated system include
mechanic, electric, hydraulic, pneumatic, microelectronics and
information technology, it has the features of high accuracy,
highly automated and highly flexible.
2, Requests for inverters (VFD)
(1) It can work normally at 300RPM speed, has good stability, high
control accuracy, fast response speed and high output torque at
low speed.
(2) It should have external forward / reverse control signal and
analog input signal.
3, Instruction for commissioning
(1) System diagram
(2) Parameters list (Take 380V, 4KW as example)
No. | Function codes | Default | Setting value | Explanation |
1 | F0-01 | 2 | 0 | Sensorless vector control (SVC) |
2 | F2-01 | Model depend | - | Set them based on the motor nameplate value |
3 | F2-02 | Model depend | - | |
4 | F2-03 | Model depend | - | |
5 | F2-04 | Model depend | - | |
6 | F2-05 | Model depend | - | |
7 | F2-11 | 0 | 2 | Rotation autotuning (disconnect the load) |
8 | F0-02 | 0 | 1 | External start / stop signal |
9 | F0-03 | 1 | 2, 3, 4 | External analog signal to control the output frequency |
10 | F0-10 | 50Hz | 100Hz | Set the max. frequency based on real request |
11 | F0-12 | 50Hz | 100Hz | Set the upper limit frequency based on real request |
12 | F0-17 | Model depend | 0.5s | Set the acceleration time based on real request |
13 | F0-18 | Model depend | 0.5s | Set the deceleration time based on real request |
14 | F1-11 | 0 | 0.5 | DC braking start frequency while stopping |
15 | F1-12 | 0 | 0s | DC braking delay time while stopping |
16 | F1-13 | 0% | 100% | DC braking current while stopping |
17 | F1-14 | 0s | 1s | DC braking time while stopping |
(3) Typical wiring diagram
4, Notices
(1) Under the SVC control mode, it must perform the auto tunning
firstly, then set the other parameters.
(2) Please pay attention to ACC/DEC time setting and also the
braking resistor’s selection.
(3) The installation environment should be safe, to avoid the iron
dust and other items to enter into inverter.