Product Details


3RT1075-6AP36 AC/DC Electrical Contactors Power Contactor DC Contactor

Overview

Version

Size

Rating of three-phase motors at 50 Hz and and 400 V

Connection method

Type

Screw terminals

Spring-type terminals

kW

Power contactors for switching motors
AC operation
Basic unitS003 ... 7.53RT201.‑.A.0.
  • With permanently mounted auxiliary switch block (SUVA-certified safety contactor)
3RT201.‑..P04‑3MA0
Basic unitS04 ... 18.53RT202.‑.A.00
  • With removable auxiliary switch block
3RT202.‑.A.04
  • With permanently mounted auxiliary switch block (SUVA-certified safety contactor)
3RT202.‑.CL24‑3MA0
Basic unitS218.5 … 373RT203.‑.A.00
  • With removable auxiliary switch block
--3RT203.‑1A.04
  • With permanently mounted auxiliary switch block
3RT203.‑.CL24‑3MA0
Basic unitS337 ... 553RT204.‑.A.00
  • With removable auxiliary switch block
--3RT204.‑1A.04
  • With permanently mounted auxiliary switch block
--3RT204.‑1CL24‑3MA0
DC operation
Basic unitS003 ... 7.53RT201.‑..B4.
  • With integrated coil circuit (diode)
3RT201.‑.FB4.
  • With permanently mounted auxiliary switch block (SUVA-certified safety contactor) and integrated coil circuit (diode)
3RT201.‑..B44‑3MA0
  • With voltage tap-off
3RT201.‑.BB4.‑0CC0
Basic unitS04 ... 18.53RT202.‑.B.40
  • With coil circuit plugged in on the front (diode assembly)
3RT202.‑.FB40
  • With removable auxiliary switch block
3RT202.‑.BB44
  • With permanently mounted auxiliary switch block (SUVA-certified safety contactor)
3RT202.‑..B44‑3MA0
  • With voltage tap-off
3RT202.‑.BB40‑0CC0
DC operation for direct control by PLC (coupling relays)
Basic unit
  • With and without integrated coil circuit
S003 ... 5.53RT201.‑..B4.
  • With integrated coil circuit
S04 ... 153RT202.‑.KB40
S218.5 … 373RT203.‑.KB40
S337 and 453RT204.‑.KB40
AC/DC operation (50/60 Hz AC and DC)
Basic unit with integrated coil circuitS05.5 ... 18.53RT202.‑.N.30
Basic unit with integrated coil circuitS218.5 … 373RT203.‑.N.30
  • With removable auxiliary switch block
--3RT203.‑1N.34
  • With permanently mounted auxiliary switch block
3RT203.‑.NB34‑3MA0
  • With voltage tap-off
3RT203.‑.NB30‑0CC0
Basic unit with integrated coil circuitS337 ... 553RT204.‑.N.30
  • With removable auxiliary switch block
--3RT204.‑1N.34
  • With permanently mounted auxiliary switch block
3RT204.‑.NB34‑3MA0
  • With voltage tap-off
3RT204.‑.NB30‑0CC0
Basic unit with conventional operating mechanismS6 ... S1255 ... 2501)3RT10..‑.A.36

Basic unit with solid-state operating mechanism

With the option of control via a separate 24 V DC control signal input

  • Fail-safe control signal input
    can be used in safety-related applications to SIL CL 3
S6 ... S1255 ... 2501)--3RT10..‑.S.36
  • Standard control signal input
1)3RT10..‑.N.36
  • Standard control signal input, with remaining lifetime indication (RLT)
1)--

3RT10..‑.P.35


Application 3RT contactors, sizes S00 to S12


Our power range:

  • Contactors for switching motors:
    • Size S00: 3RT201 up to 7.5 kW
    • Size S0: 3RT202 up to 18.5 kW
    • Size S2: 3RT203 up to 37 kW
    • Size S3: 3RT204 up to 55 kW
    • Sizes S6 to S12: 3RT10 up to 250 kW
    • Sizes S10 and S12: 3RT12 up to 250 kW
    • Size 14: 3TF6 up to 450 kW
Standards

IEC/EN 60947‑1,
IEC/EN 60947‑4‑1,
IEC/EN 60947‑5‑1 (auxiliary switches)


Technical data

Power contactor, AC-3 400 A, 200 kW / 400 V AC (50-60 Hz) / DC operation 220-240 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S12 Busbar connections Drive: conventional screw terminal
Product brand nameSIRIUS
Product designationPower contactor
Product type designation3RT1
General technical data
Size of contactorS12
Product extension
● function module for communicationNo
● Auxiliary switchYes
Surge voltage resistance
● of main circuit rated value8 kV
● of auxiliary circuit rated value6 kV
maximum permissible voltage for safe isolation
● between coil and main contacts acc. to EN 60947-1690 V
Protection class IP
● on the frontIP00; IP20 on the front with cover / box terminal
● of the terminalIP00
Shock resistance at rectangular impulse
● at AC8,5g / 5 ms, 4,2g / 10 ms
● at DC8,5g / 5 ms, 4,2g / 10 ms
Shock resistance with sine pulse
● at AC13,4g / 5 ms, 6,5g / 10 ms
● at DC13,4g / 5 ms, 6,5g / 10 ms
Mechanical service life (switching cycles)
● of contactor typical10 000 000
● of the contactor with added electronics-compatible auxiliary switch block typical5 000 000
● of the contactor with added auxiliary switch block typical10 000 000
Reference code acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750K
Reference code acc. to DIN EN 81346-2Q
Ambient conditions
Installation altitude at height above sea level
● maximum2 000 m
Ambient temperature
● during operation-25 ... +60 °C
● during storage-55 ... +80 °C
Main circuit
Number of poles for main current circuit3
Number of NO contacts for main contacts3
Operating voltage
● at AC-3 rated value maximum1 000 V
Operating current
● at AC-1 at 400 V
— at ambient temperature 40 °C rated value430 A
● at AC-1
— up to 690 V at ambient temperature 40 °C rated value430 A
— up to 690 V at ambient temperature 60 °C rated value400 A
— up to 1000 V at ambient temperature 40 °C rated value200 A
— up to 1000 V at ambient temperature 60 °C rated value200 A
● at AC-2 at 400 V rated value400 A
● at AC-3
— at 400 V rated value400 A
— at 500 V rated value400 A
— at 690 V rated value400 A
— at 1000 V rated value180 A
● at AC-4 at 400 V rated value350 A