3RT1056-6AP36 3 Pole 400vac 90kw Contactor Switch

Certification:CE UL SA
Model Number:3RT1056-1AF36 3RT1056-1AP36 3RT1056-6AF36 3RT1056-6AP36
Minimum Order Quantity:1 pcs
Delivery Time:2-5 work days
Payment Terms:T/T, Western Union, MoneyGram
Place of Origin:GERMANY
Contact Now

Add to Cart

Verified Supplier
Address: Liushi Town,Yueqing City,Zhejiang Province,China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

3RT1056-6AP36 3POLE 400VAC CONTROL CONTACTOR 90kW DC OPERATION 220-240V CONTACTOR

Power contactor, AC-3 150 A, 75 kW / 400 V AC (50-60 Hz) / DC operation 110-127 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S6 Busbar connections Drive: conventional screw terminal

Motor protection

3RT1 contactors

3RB2 electronic overload relays can be mounted on the 3RT1 contactors for protection against overload.

Plant and application monitoring

For monitoring and measuring in the application, 3RR2 monitoring relays can be mounted on the 3RT2 contactors.

Ratings of three-phase motors

The quoted rating (in kW) refers to the output power on the motor shaft (according to the nameplate).

The power rating specifications of the contactors in kW (in accordance with IEC 60947-4-1, Table G) are guide values for 4-pole standard motors at 50 Hz AC and specified voltage (e.g. 400 V AC). The actual starting and rated data of the motor to be switched must be considered when selecting the units. The motor current, motor protection device and the permissible contactor current according to the utilization category must be aligned with each other.

Operating mechanism types

3RT1 contactors

The following control and/or operating mechanism versions are available in sizes S6 to S12:

  • Standard operating mechanism with economy circuit for AC and DC operation (switchover from closing coil to holding coil)
  • Solid-state operating mechanism
    Overvoltage damping of the operating mechanism coil is already integrated in the electronics for contactors with solid state operating mechanisms. The operating mechanisms are powered via a supply voltage with an operating range from 0.8 to 1.1 x Us, optionally also controlled depending on the chosen mode of operation. Alternatively, control is also possible via the separate 24 V DC control signal input. Various rated voltage ranges for AC/DC control are available.

    The following versions are available:
    • With two operating modes: Direct control or via CPU input
    • As above, but with additional remaining lifetime indicator (RLT)
    • With fail-safe PLC input for simplification of safety applications (without mode of operation selection)

Technical data

General technical data
Size of contactor S6
Product extension
● function module for communication No
● Auxiliary switch Yes
Power loss [W] for rated value of the current
● at AC in hot operating state 39 W
● at AC in hot operating state per pole 13 W
Power loss [W] for rated value of the current without load current share typical 5.2 W
Surge voltage resistance
● of main circuit rated value 8 kV
● of auxiliary circuit rated value 6 kV
maximum permissible voltage for safe isolation
● between coil and main contacts acc. to EN 60947-1 690 V
Protection class IP
● on the front IP00; IP20 on the front with cover / box terminal
● of the terminal IP00
Shock resistance at rectangular impulse
● at AC 8,5g / 5 ms, 4,2g / 10 ms
● at DC 8,5g / 5 ms, 4,2g / 10 ms
Shock resistance with sine pulse
● at AC 13,4g / 5 ms, 6,5g / 10 ms
● at DC 13,4g / 5 ms, 6,5g / 10 ms
Mechanical service life (switching cycles)
● of contactor typical 10 000 000
● of the contactor with added electronics-compatible auxiliary switch block typical 5 000 000
● of the contactor with added auxiliary switch block typical 10 000 000
Control circuit/ Control
Type of voltage of the control supply voltage AC/DC
Control supply voltage at AC
● at 50 Hz rated value 220 ... 240 V
● at 60 Hz rated value 220 ... 240 V
Control supply voltage at DC
● rated value 220 ... 240 V
Operating range factor control supply voltage rated value of magnet coil at DC
● initial value 0.8
● Full-scale value 1.1
Operating range factor control supply voltage rated value of magnet coil at AC
● at 50 Hz 0.8 ... 1.1
● at 60 Hz 0.8 ... 1.1
Design of the surge suppressor with varistor
Apparent pick-up power of magnet coil at AC
● at 50 Hz 300 V·A
Inductive power factor with closing power of the coil
● at 50 Hz 0.9
Apparent holding power of magnet coil at AC
● at 50 Hz 5.8 V·A
Inductive power factor with the holding power of the coil
● at 50 Hz 0.8
Closing power of magnet coil at DC 360 W
Holding power of magnet coil at DC 5.2 W
Closing delay
● at AC 20 ... 95 ms
● at DC 20 ... 95 ms
Opening delay
● at AC 40 ... 60 ms
● at DC 40 ... 60 ms
Arcing time 10 ... 15 ms
Control version of the switch operating mechanism Standard A1 - A2


Main models:

3RT1056-1AF36 3RT1056-1AP36 3RT1056-1AV36 3RT1056-6AF36 RT1056-6AP36 RT1056-6AV36

3RT1056-6AP36 3 Pole 400vac 90kw Contactor Switch

3RT1056-6AP36 3 Pole 400vac 90kw Contactor Switch

Shipping :
1. We will ship most items within 3-5 working days after the payment is reached.
2. All the goods will be tested before shipment.
3. We can ship to you by DHL/TNT/UPS/EMS/Fedex... Or ship as your requirement.

Best Quality Assurance:
1. We only provide the original new items, 100% make sure the best quality!
2.1 year warrant GUARRANTEE OF QUALITY

China 3RT1056-6AP36 3 Pole 400vac 90kw Contactor Switch supplier

3RT1056-6AP36 3 Pole 400vac 90kw Contactor Switch

Inquiry Cart 0