Add to Cart
Salt water electrolysis sodium hypochlorite generator for water plant
Brief Introduction
The GEEMBLUE EC system generates a 0.8 % sodium hypochlorite solution through the electrolysis of salt water , consuming only water, salt and electricity. By producing hypochlorite on-site and on-demand, the system eliminates concerns associated with transportation and storage of chlorine gas or commercial sodium hypochlorite solutions, making it ideal for any medium to large scale application requiring chlorination.
Sodium hypochlorite turn into hypochlorous acid by hydrolysis in water, and turn into nascent oxygen [O] in further step, which having ultra strong oxidation to effect the protein of thalli and virus, and terminate pathogenic microorganisms. Besides that, during the reaction of hypochlorous acid, it’s not only having effects on cell wall and viral coat, but due to its small volume and no electrical charge, it’s also permeate into germ or virus generate oxidation reaction with the organic polymer like protein, nucleic acid and enzyme, and thus to kill pathogenic microbes. What’s more, the chlorine ion generated by hypochlorous acid will change the osmotic pressure significantly, cause death of cell by lost of activity.
Specification
GTL-5000 | GTL-8000 | GTL-10000 | GTL-15000 | GTL-20000 | |
---|---|---|---|---|---|
Chlorine Capacity | 5Kg/hr | 8Kg/hr | 10Kg/hr | 15Kg/hr | 20Kg/hr |
Water treatment Capacity(At 1ppm dosing) | 100mld | 160MLD | 200MLD | 300MLD | 400MLD |
Salt Consumption | 3.5kg/kg Cl2 | 3.5kg/kg Cl2 | 3.5kg/kg Cl2 | 3.5kg/kg Cl2 | 3.5kg/kg Cl2 |
Power Consumption | 4.0kw/ kg Cl2 | 4.0kw/ kg Cl2 | 4.0kw/ kg Cl2 | 4.0kw/ kg Cl2 | 4.0kw/ kg Cl2 |
Concentration of HYPO | 5000~8000ppm | 5000~8000ppm | 5000~8000ppm | 5000~8000ppm | 5000~8000ppm |
Production Flow Rate | 625~1000 L/hr | 1000~1600L/hr | 1250~2000L/hr | 1875~3000L/hr | 2500~4000L/hr |
Advantage
Ease of installation and maintenance
Installation Flexibility:
Geemblue sodium hypochlorite generator is perfect for retrofit
applications or installation in existing buildings since it can
pass through a standard doorway. The floor-mounted
transformer/rectifier cabinet on 3.75 kg/h and 5.00 kg/h (195
lb/day and 260 lb/day) is typically installed adjacent to the
generator to minimize the length of interconnecting power cables.
Plug-and-Play Convenience:
The electrolyzer system is shipped pre-assembled, pre-wired, and
tested to verify hypochlorite production. Once the system is on
site the electricity supply, brine solution and process water
connections have to be connected to the skid. The common outlet
pipe for hypochlorite and hydrogen solution
is piped to the hypochlorite storage tank. For these works, the
correct installation and regular maintenance, we recommend our
specially trained technicians.
Less Maintenance, Reduced Downtime:
All serviceable components are strategically arranged on the skid
as to facilitate quick access by maintenance personnel. The process
water and brine management subassembly is panel mounted on the
skid. The electrolyzer is situated on the frame so that it may be
accessed by the operator while standing upright. Flexible hydraulic
hose and electrical cables to the electrolyzer make for easy
connections and adjustment if needed. Piping and electrical
connections are provided for the acid-cleaning system
Application
Chlorination of potable water supplies
Food washing / processing treatment
Dairies / Breweries cleaning in place (CIP)
Cooling tower biocide treatment
Secondary disinfection
Industrial chlorination treatments
Swimming & Spa pool disinfection