16A Rccb RCCB Circuit Breaker Rcd Electrical Safety Switch SFL5-63

Brand Name:SEFIE
Certification:CB,CE,ROHS
Model Number:SFL5-63
Minimum Order Quantity:2000-3000
Delivery Time:14 days after receipt of deposit
Place of Origin:WenZhou,China
Contact Now

Add to Cart

Active Member
Location: Wenzhou Zhejiang China
Address: Xiangyang Industrial Zone,Liushi,Wenzhou,china
Supplier`s last login times: within 45 hours
Product Details Company Profile
Product Details

SEFIE / 2P 6KA rccb 16A / 10A / 20A / 25A / 32A / 40A / 63A residual current circuit breaker


The residual current device(RCD) works with no extra power supply to the operating mechanism. It compares the magnitude of the currents through the neutral and phase conductors. The conductors are coiled on toroid and together with the secondary winding form a measurement transformer. The power conductors are coiled in such a way that the magnetic fields generated at electrical current flow through them are mutually neutralized. At failure in the insulation of some of the conductors or at presence of a person under voltage, the system is misbalanced and the magnetic fields can not be neutralized. This residual field generates in the secondary current winding, called current leakage. The device breaks when the value of this current exceeds the limit value of the RCD. Every people from any profession and any cultural level are in close contact with electrical energy at any hour of the day and they may encounter residual currents. Under normal conditions, benefits from electrical energy are countless. However, damages arising from an insulation error are also really huge. Every year, many individuals become victim of electrical accidents. Therefore, use of residual current protection devices has been rendered mandatory in many countries and our country.


typeIn/AI△n/AResidual Current (I△)Is Corresponding To The Following Breaking Time
I△n2I△n5I△n5A ,10A ,20A ,50A ,100A ,200A ,500A

general

type

any

value

any

value

0.30.150.040.04Max Break-time
S type≥25>0.030.50.20.150.15Max Break-time
0.130.060.050.04Min non-driving time
G type

any

value

any

value

0.50.20.150.15Max Break-time
0.010.010.010.01Min Non-driving time
The general type RCBO whose current I△n is 0.03mA or less can use 0.25A instead of 5I△n


TypeTripping current I△/A
AC0.5I△n<I△<I△n
ALagging AngleI△n>0.01AI△n≤0.01A
00.35I△n≤I△≤1.4I△n0.35I△n≤I△n≤2I△n
900.25I△n≤I△≤1.41I△n0.25I△n≤I△≤2I△n
1350.11I△n≤I△≤1.4I△n0.11I△n≤I△≤2I△n