Add to Cart
VFD Ration Batching Controller Digtal Weight Indicator For 5-Material Ration Batching Scale
Main Features:
Pictures
Model Panel-mounting Operation Interface
Keypad Operation
If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.
Menu Operation | |
Key Name | Description |
【MENU】 | Enter Main Menu / Exit. |
【ENT】 | Enter / Save / Alarm Acknowledge. |
【◄】 | Cursor shifts left. |
【►】 | Cursor shifts right. |
【▲】 | Display the previous interface or option. Digit input: +1. |
【▼】 | Display the next interface or option. Digit input: -1. |
Quick Operation | |
【Ñ】 * |
|
【SET】 | M1~M5 Target Values setting. |
【G/N】 | Gross Weight / Net Weight display switch. |
【→C←】 【CAL】 * | Load Calibration. |
【→0←】 【ZERO】 * |
|
【→T←】 【TARE】 * |
|
【,】* | Record Query. |
【/】* | Clear Screen: Clear the display value of Tatal Feeding Weight, Totalized Weight and Batch Count. |
【‡】* | Time display and setting. |
【±】 | ‘+’/‘-’ switch. |
【6】 | Main Display Interface:
Record Query state: Print Historical Batch Record. |
【ENT】 | Pause State:
|
*: Keep the key pressed for 2 seconds.
State Indication
Sign | Description |
[GROSS] | Gross Weight display. |
[NET] | Net Weight display. |
[LOCK] | ON: Key-locked. OFF: Key-unlocked. |
[◣◢] | Weight is stable: Weight Variance per [107] ‘Stablity Judging Time’ is in [106] ‘Stablity Judging Range’. |
[→0←] | The present Gross Weight or Net Weight display value is in ‘Display Value Auto-Zero Range’. |
[kg/t/g] | Weight unit. |
[ NUM] | Material No. display. |
[ PCS] | Batch Count display. |
[TOT] | Totalized Weight display. Total Feeding Weight display. |
[SET] | Target Value display. Parameter setting state. |
[RUN] | ON: Running state. Blinking: Pause state. OFF: Stop or Calibrating state. |
[ZERO] | Net Weight ≤ Non-load Zero Range. |
[NZ] | It’s allowed to do Zero Fine Adjustment. |
[SP1] | High-speed Feeding. |
[SP3] | Low-speed Feeding. |
[FILL] | Stop state: Weight value is increasing. |
Running state: It’s in the feeding process. | |
[COMP] | ON: It’s doing comparation between Feeding Weight and Target Value. OFF: It turns off in Comparing-prohibited Time. |
[DEV] | Positive/Negative Deviation Alarm. |
[FALL] | ON: Fall Value Auto Correction function is open. |
[DISC] | Stop state: Weight value is reducing. |
Running state: It’s in the dumping process. | |
[HH] | Gross Weight Upper Limit Alarm. |
Model Panel-mounting Installation
Model AC85~264V/AC220V Terminal
System Diagram for M1~M5 Ration Batching System