Technical Specifications

  • Power Supply: AC220V±15%, 50/60Hz, Max. 10W.
  • Loadcell Excitation Voltage/Current: DC10V/250mA.
  • 8 Loadcells[350Ω] connectable.
  • Weighing Signal Input Range: 0~25mV.
  • 3 Normally Open Switch Inputs [DI].
  • 4 Normally Open Relay Outputs [DO]: AC250V/DC24V, 1A.
  • 1 Analog Signal Output [AO]: 4~20mA, 0.05%FS.
  • COM1: Fixed RS232&RS485. Free to use one of them.
  • COM2: Optional RS232/RS485/RS422/Profibus-DP/Ethernet.
  • Connect Host IPC, Remote Display, Printer&Wireless Module.
  • Outline Size [W×H×D]: 160 × 84 × 188 mm.
  • Panel Cut-out Size [W×H]: 151 × 76 mm.
  • Operating Temperature: -25℃~+45℃.
  • Protection Level of Front Panel: IP65.
  • Accuracy Grade: III.
  • Verification Accuracy: 0.02%.
  • Static Weighing Accuracy: 0.2%~0.5%.

Model Panel-mounting Installation


Model

Outline Size

W×H×D [mm]

Front Panel Size

W1×H1 [mm]

Box Body Size

W×H [mm]

Panel Cut-out Size

W×H [mm]

DC24V170×91×184170×91150×75151×76
AC220V160×84×188160×84150×75151×76


Keypad Operation

If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.

Menu Operation
Key NameDescription

【MENU】

【ESC】

(【LOCK】)

Enter Main Menu.

Exit.

Keep it pressed for 2 seconds: Key-locking / Key-unlocking.

【ENT】Enter/Save/Clear Alarm.
【◄】Cursor shifts left.
【►】Cursor shifts right.
【▲】

Display the previous option.

Digit input: +1.

【▼】

Display the next option.

Digit input: -1.

Quick Operation
【G/N】APL0 Hopper Weighing Mode: Gross Weight / Net Weight display switch.

APL1 Ration Batching Mode: Gross Weight / Net Weight / Feeding Weight display Switch.

  • [A./b./c.]: Feeding Weight of Material M1/M2/M3.
  • [t.]: Total Feeding Weight.
【ZERO】
  • [-ZEro-]: Zero Calibration with Power-down Protection and Clearing Tare Weight.
  • [≡ZEro≡]: Manual Zero without Power-down Protection and without Clearing Tare Weight.
  • The controller will switch to Gross Weight display.
【TARE】
  • [≡tArE≡]: Manual Tare without Power-down Protection.
  • [-PStr-]: Preset Tare Weight with Power-down Protection.
  • [-rStr-]: Clear Tare Weight with Power-down Protection.
  • The controller will switch to Net Weight display.
【CAL】
  • [-LoAd-]: Load Calibration.
【▲】【▼】** Keep it pressed for 2 seconds: Setpoint parameters setting.
【PRINT】Print Weighing/Batching Report.

Hopper Weighing Mode :

Material M1 Ration Feeding Mode


Material M1~M3 Ration Batching Mode


China VFD Panel Mounting Material Level Weighing Controller For Hopper Scale And Platform Scale supplier

VFD Panel Mounting Material Level Weighing Controller For Hopper Scale And Platform Scale