High Protecting Level Measuring Controller Electronic Weighing Indicator For 1-3 Channels Force Measuring Systm
Calibration notic
Note:
Technical Specifications
Power Supply: DC24V±20%, Max. 5W.
Loadcell Excitation Voltage/Current: DC5V/120mA.
8 Loadcells[350Ω] connectable.
Transmitter Excitation Voltage/Current: DC12V/100mA.
Optional weighing input signal mV, V and mA.
【mV】Signal Input Range: 0~19.5mV.
【V】Signal Input Range: 0~2.5V, 0~5V, 0~10V.
【mA】Signal Input Range: 0~20mA.
2 Normally open/closed Relays [DO]: AC250V/DC24V, 1A.
1 Analog Signal Output [AO]: 0~20mA, 0.05%FS.
COM1: RS232.
COM2: RS485.
Connect Host IPC[Modbus] & Remote Display.
Outline Size [W×H×D]: 107 × 60 × 100 mm.
Panel Cut-out Size [W×H]: 94 × 47 mm.
Operating Temperature: -25℃~+45℃.
Protection Level of Front Panel: IP65.
Accuracy Grade: III.
Verification Accuracy: 0.03%.
Static Weighing / Force Measuring Accuracy: 0.2%~0.5%.
Pictures
Main Menu | Second Menu | ||
Sign | Function | Sign | Description |
F1-SEt | Parameter Setting | -SCAL- | Scale parameters setting. |
-CALP- | Calibration parameters setting. | ||
-SEtP- | Setpoint parameters setting. | ||
-SErP- | Communication parameters setting. | ||
-dISP- | User interface parameters setting. | ||
F2-CAL | System Calibration | -ZEro- | Zero Calibration without loading on the weigher to correct Zero Value. |
-dAtA- | Data Calibration: Input the specification parameter values of loadcell [Total Capacity and Output Sensitivity] according to the actual configuration of the weighing system to correct Span Coefficient. If there is no access to get the specification parameter values for Data Calibration, then it’s necessary to do Load Calibration. | ||
-LoAd- | Load Calibration: After doing Data Calibration, if there are conditions for Load Caliration, do Load Caliration with loading standard weight on the weigher to correct Span Coefficient further for higher weighing accuracy. | ||
F3-rEC | Unused. | ||
F4-CLn | Data Clearing | --CLS- | Clear Screen: Clear the display value of Net Weight of Present Batch, Totalized Net Weight and Batch Count. |
F5-Loc | Key-locker | -oPEn- | Key-unlocking. |
-Locc- | Key-locking. | ||
-PASS- | Password Set. Exfactory Passwords:
|
LED light | Description |
[RUN] | OFF: Real-time Force Value tracking display state. ON: Peak Value Detecting Result holding display state [Peak Value Detecting Process Finished]. Blinking: Peak Value tracking display state [In Peak Value Detecting Process]. |
[AL1] | Real-time Resultant Force or Resultant Force Peak Value Upper Limit Alarm. Refer to Parameters [200]&[202]. |
[AL2] | Real-time Resultant Force or Resultant Force Peak Value Lower Limit Alarm. Refer to Parameters [201]&[202]. |
Installation