Batching Weighing Controller Weight Display Batching Weighing Indicator BST106-B68(U)


Main Applications

  • 4-Material Ration Batching Scale.

Main Features

  • EMC design with high anti-jam for industrial environment.
  • DC24V power input with reverse polarity protection.
  • 32-bit ARM CPU with 48MHz clock & high arithmetic speed.
  • 6+8 Red LED digital tubes for English&digit display.
  • 24-bit ∑-△ADC with internal resolution 1/1,000,000.
  • High sampling frequency 400Hz.
  • Special Anti-vibration Digital Filtering Algorithm for precise weighing, stable display and rapid response.
  • Auto Zero Tracking.
  • Fall Value Auto Correction.
  • Auto Re-feed for Negative Deviation Alarm.
  • Target Batch Count Control.
  • Auto Pause for Gross Weight Upper Limit & Deviation Alarm.
  • ‘Manual Pause’ Operation.
  • Batching Process Power-off Protection.
  • 2-speed[high/low] feeding control by DOs or AOs.
  • Definable AO/COM[Communication Port].
  • Recipe Number: 1.

DI/DO Function Definition

CN1 [DI]
No.PinSignal NameDescription
1COMCOMDI Common Terminal [DC-].
2DI1AUTO

Auto/Manual.

ON: Auto state.

OFF: Manual state / Emergency Stop.

3DI2START

Start / Clear Alarm.

In running process: Clear Alarm.

Pause state: Clear Alarm & Recover Running.

OFF→ON→OFF.

4DI3PAUSE

Manual Pause.

OFF→ON→OFF.

5DI4DUMP_I

Manual Dump.

1. Stop state:

ON: Manual Dump; OFF: Stop.

2. In the Auto-batching process

If [312] ‘Dumping Mode’ = ‘0. HAnd, it’s necessary to input the DI signal ‘Manual ‘Dump’ (OFF→ON→OFF) for triggering the dumping process.

6DI5STOP

Normal Stop [Last Batch].

OFF→ON→OFF: The batching process will stop automatically after the present batch finished.

7DI6SP3_I

Manual Dribble Re-feed.

Valid at Pause state with Mn’s Low Tolerance Alarm.

ON: Start Mn’s Dribble Feed.

OFF: Stop Mn’s Dribble Feed.


System Diagram for M1~M4 Ration Batching System



Application:


How long is the warranty period?

The warranty period for our products is 12 (twelve) months.

If the products from SUPMETER are proved to be unable to work normally due to unartificial reasons, and the problems can't be solved by customers under the technical support from SUPMETER, then customers can send the problematic items back to SUPMETER. SUPMETER is RESPONSIBLE to MEND (or REPLACE when necessary) them FREE OF CHARGE.

(Note: if after checking, the returned goods are proved to be in good condition, the trouble is resulted to be caused by improper operation by customers, SUPMETER is IRRESPONSIBLE to bear the shipping & other charges related to the returning.)


China Weight Display Batch Weighing Controller , Weighing Indicator Controller supplier

Weight Display Batch Weighing Controller , Weighing Indicator Controller

Inquiry Cart 0