Add to Cart
High Quality Accurate Precise Point-to-point ESD Surface Resistance Tester Kits
Products Description:
Range of measured resistance values | ||
10V | Less than 10e6 ohms / m2 | Electric conduction |
100V | 10e6-10e11 ohms / m2 | Antistatic |
100V | Greater than 10e12 ohms / m2 | Insulation |
Relative humidity:10% - 90% RH
Temperature:32.F-100. F(0℃-37.8℃)
High-precision:
-Full range
-2*5-pound hammers
-LCD digital display
-It can measure table mats, floor coatings, paintwork, wristbands,
work clothes, shoes (shoe covers), bags and containers
Product details:
SJC030B megger is designed according to EOS / ESD, CECC, ASTM and
UL test procedures. It is used to measure the impedance or
resistance of all conductive, antistatic and electrostatic
discharge surfaces. It is easy to use, high quality and high
reliability. It can also measure the relative humidity and
temperature affecting electrical performance.
Measure impedance temperature and humidity. "Humidity and
temperature affect impedance, so it must be measured" Measure the
surface impedance 10e3-10e12 ohms / m2, and measure the resistance
10e3-10e12 ohms.
Product physical characteristics:
1.Measure impedance, temperature and humidity to comply with ESD
standard, S4 1,S7. S11 and S11.11;
2.0e3-10e12 ohm / range, which can test the electrical properties
of various materials;
3.0 V / 100 V measurement scale, suitable for worktable and ground
specified in the standard;
4.Plastic instrument protection box to prevent instrument damage;
5. Light weight, simple packaging and easy to carry;
6. LCD digital display, easy to use and easy to read;
7. Automatic power-off function to prolong the service life of the
battery;
8. Automatically return to zero to ensure accuracy;
9.5-pound probe, all in accordance with ASTM, EOS and CECC
standards.
Operation manual:Before measurement, first ensure that the surface to be measured is clean and free of pollution
Surface resistance measurement:
This measurement method is in accordance with EOS / ESD-S.4.1
Measurement requirements are to measure the resistance between two
points independent of grounding. The measurement results obtained
by this measurement method are related to the treatment of the
measured object, the distance between two 5-pound probes and other
factors. Therefore, correct measurement procedures shall be
selected and tested under the same required measurement conditions
each time.
A. Insert the connecting plug into the two 35 mm sockets of the
meter and connect the banana plug with the two 5-pound probes;
B. Place two probes on the surface of the object to be measured
according to the measurement procedures;
C. Select the desired voltage value (10 volts or 100 volts) ;
D. Press "off" until the selected voltage value (10V or 100V) is
displayed, continue to press "off" until the measured resistance
(in ohms), and the relative humidity and temperature are displayed
on the LCD.
Different from other LED surface resistance testers, the LCD display of sjc-030b will display the measured accurate value. For example, 27 megaohms (27 * 10e7) will be dis27e07ohms / sq.
Picture: