IEC60320-3 High Precision Go and Not Go Gauges for Appliance Couplers made of S16 Steel

1. Introduction

The appliance couplers go and not go gauges are strictly designed according to EN60320-3:2014 figure 2 to figure 31, for testing the appliance couplers (C1 to C24, F, H, J, L) for household and similar general purpose. The gauges are used with force as mentioned in the relevant standard sheet of the gauge to perform insertion compliance test. And the gauges and pins are made of hardened steel.


2. Specification

StandardFigure number and gauge nameTest purpose
IEC60320-3Figure 2 - Go Gauge for Connectors to Standard Sheet C1To verify if connector C1 can fully insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 3 - Go Gauge for Connectors to Standard Sheet C5To verify if connector C5 can fully insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 4 - Go Gauge for Connectors to Standard Sheet C7To verify if connector C7 can fully insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 5 - Go Gauge for Side-entry Connectors to Standard Sheet C7To verify if the connector C7 can fully insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 6 - Not Go Gauge for Connectors to Standard Sheets C1To verify if connector C1 cannot insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 7 - Not Go Gauge for Connectors to Standard Sheets C1, C5 and C7To verify if connectors C1, C5 and C7 cannot insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 8 - Not-Go Gauge for Connectors to Standard Sheets C1 and C7To verify if connectors C1 and C7 cannot insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 9 - Blades for Checking The Resistance Against Deformation of The Front Part of The Connectors to Standard Sheet C7For 2.5A connector for class II equipment according to standard sheet C7 shall be sufficiently resistance to deformation. The blades is used for compliance test.
IEC60320-3Figure 10 - Not-Go Gauge for Appliance Inlets to Standard Sheet C8, C8A and C8BWhen the gauge is inserted between the ridges of the appliance inlets C8, C8A and C8B with a force of 30n, it shall not touch the bottom of the inlet
IEC60320-3Figure 11 - Go Gauge for Connectors to Standard Sheet C9To verify if connector C9 can fully insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 12 - Not Go Gauge for Connectors to Standard Sheet C9To verify if connector C9 cannot insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 13 - Go Gauge for Appliance Inlets to Standard Sheets C10To verify if the gauge can fully insert into appliance inlet C10 with a force not exceeding 60N
IEC60320-3Figure 14 - Go Gauge for Connectors to Standard Sheet C13To verify if connector C13 can fully insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 15 - Not Go Gauge for Connectors to Standard Sheets C13 and C17To verify if connectors C13 and C17 cannot insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 16 - Go Gauge for Appliance Inlets to Standard Sheets C14, C16 and C18To verify if the gauge can fully insert into appliance inlets C14, C16 and C18 with a force not exceeding 60N
IEC60320-3Figure 17 - Go Gauge for Connectors to Standard Sheet C15To verify if connector C15 can fully insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 18 - Go Gauge for Connectors to Standard Sheet C17To verify if connector C17 can fully insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 19 - Go Gauge for Connectors to Standard Sheet C19To verify if connector C19 can fully insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 20 - Go Gauge for Appliance Inlets to Standard Sheets C20 and C24To verify if the gauge can fully insert into appliance inlets C20 and C24 with a force not exceeding 60N
IEC60320-3Figure 21 - Go Gauge for Connectors to Standard Sheet C21To verify if connector C21 can fully insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 22 - Go Gauge for Appliance Inlets to Standard Sheet C22To verify if the gauge can fully insert into appliance inlets C22 with a force not exceeding 60N
IEC60320-3Figure 23 - Go Gauge for Connectors to Standard Sheet C23To verify if the gauge can fully insert into appliance inlets C23 with a force not exceeding 60N
IEC60320-3Figure 24 - Not Go Gauge for Connectors to Standard Sheets C13, C15 and C17To verify if connectors C13, C15 and C7 cannot insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 25 - Go Gauge for Connectors to Standard Sheet C15ATo verify if connector C15A can fully insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 26 - Go Gauge for Appliance Inlets to Standard Sheet C16ATo verify if connector C16A can fully insert into the gauge with a force not exceeding 60N
IEC60320-3Figure 27 - Go Gauge for Appliance Outlets to Standard Sheet FTo verify if the gauge can fully insert into appliance inlet F with a force not exceeding 60N
IEC60320-3Figure 28 - Go Gauge for Appliance Outlets to Standard Sheet HTo verify if the gauge can fully insert into appliance inlet H with a force not exceeding 60N
IEC60320-3Figure 29 - Go Gauge for Appliance Outlets to Standard Sheet JTo verify if the gauge can fully insert into appliance inlet J with a force not exceeding 60N
IEC60320-3Figure 30 - Go Gauge for Appliance Outlets to Standard Sheet LTo verify if the gauge can fully insert into appliance inlet L with a force not exceeding 60N
IEC60320-3Figure 31 - Gauges for Checking Point of First Contact (0.2A)The appropriate gauge shall be applied to the entry hole of each socket contact of the connector with a force not exceeding 5N. When the gauge is fully inserted, the longer pin of the gauge (contact gauge) shall make contact and the shorter pin (no contact gauge) shall not contact contact.
Figure 31 - Gauges for Checking Point of First Contact (2.5A)
Figure 31 - Gauges for Checking Point of First Contact (6A)
Figure 31 - Gauges for Checking Point of First Contact (10A)
Figure 31 - Gauges for Checking Point of First Contact (16A-E)
Figure 31 - Gauges for Checking Point of First Contact (16A-L)

3. Picture

4. FAQ

1). Can you provide third-lab calibration certificate for the appliance couplers go and not go gauges?

Answer: Yes, it can be deliveried with the third-lab calibration certificate authorized by ISO17025, but the cost is additional.


2). What is material of the gauges?

Answer: The gauges are made of S16 anti-corrosion mirror steel which with magnetic and rust-proof characteristic


3). What package will be used for shipment?

Answer: The device will be packed in a silver aluminum box with sponge protection.


4). What's the warranty of the device?

Answer: The warranty is 12 months upon receipt of the device and we will provide life-long maintenance. Within the warranty period, we will provide the free spare parts for your replacement, Outside the warranty period, we will only charge the cost of the accessories

China IEC60320-3 High Precision Go And Not Go Gauges For Appliance Couplers Made Of S16 Steel supplier

IEC60320-3 High Precision Go And Not Go Gauges For Appliance Couplers Made Of S16 Steel

Inquiry Cart 0