150 Kva Perkins Diesel Generator Genset Commercial 400 Rated Voltage 50/60Hz

Brand Name:SHX
Certification:ISO9001:2015, CE, TUV, BV
Model Number:SPF350
Minimum Order Quantity:1 Set
Delivery Time:20 working days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Active Member
Location: Foshan Guangdong China
Address: No. 1, Xinglong 2nd Road, Guanglong Industrial Zone, Chencun Town, Shunde, Foshan, China.
Supplier`s last login times: within 35 hours
Product Details Company Profile
Product Details

150 Kva Perkins Diesel Genset 400 Rated Voltage 50/60Hz Commercial Generators


General Feature:


1. Prime power 120KW / 150KVA, standby power 132KW / 165KVA
2. Engine brand: Perkins
3. Alternator: Stamford
4. Water-cooled
5. Manual start / auto start
7. Soundproof canopy is optional
8. 230 / 400V AC, 50Hz / 60Hz, 0.8pF three-phase and four wires alternating current output



Genset Specifications:


Genset modelSPS165
Genset rated power120KW / 150KVA
Rated voltage400/230V (adjustable)
Rated current216Amps
Frequency50 Hz / 60 Hz
Power factor0.8 Lagging
Connecting type3 phase 4 wire
Cooling systemClosed cycle water-cooled with fan, water tank
Overall dimension (L×W×H) mm2750*850*1150
Gross weight (kg)1250

Engine Specifications:


Diesel Engine
BrandPERKINS
Model1106A-70TAG2
Engine type6 cylinders in line, 4 stroke, direct injection
AspirationTurbocharged and intercooled
Rotating speed1500 RPM
Engine cooling systemWater-cooled
Fuel injection systemElectronic
Starting methodBy 24V batteries
Engine filter systemDry type air filter ,fuel filter, oil filter, water filter
Displacement(L)7
Bore×Stroke(mm)105×135
Compression ratio16:1
100% Load fuel consumption (l/h)≤205
Lube capacity(L)16.5

Alternator Specifications:


Alternator
BrandSTAMFORD
ModelUCI274F
Excite typeBrushless self-excited AVR regulation
Connecting type3 phase 4 pole
Steady frequency change0.50%
No load voltage≥95%-105%
Steady voltage≤±1%
Insulation classClass H
Protection gradeIP23

Operation Display:

  • Unit voltage, tri-phase load current and frequency display
  • Water temperature, oil pressure display
  • Fuel level, fuel temperature display
  • Audible and visual alarm lamps and buzzers
  • Starting system: DC alternator is used to start engine
  • Short circuit protection: MCCB air switch
  • Cooling system: Combined cooling water tank fitted to meet the requirement of radiation at ambient temperature 40 degree
  • Filter system: Oil, fuel and air filter
  • Accessories: Exhaust elbow, bellow, muffler



China 150 Kva Perkins Diesel Generator Genset Commercial 400 Rated Voltage 50/60Hz supplier