Three Phase Output Ups Load Bank , Ocean Engineering Resistance Load Bank

Brand Name:KAIXIANG
Certification:ISO9001
Model Number:AC400-715K-RL
Minimum Order Quantity:1 set
Delivery Time:Within 30 working days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Active Member
Location: Shijiazhuang Hebei China
Address: No33 Wangshan Road, Green Island Economic Development Zone, Shijiazhuang, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Three Phase Output Ocean Engineering 400V 715KVA Inductive Load Bank

Product description


The “load” of a resistive load bank is created by the conversion of electrical energy to heat by power resistors. This heat must be dissipated from the Load Bank, either by air or by water, by forced means or convection.


Technical Parameter


Rating Voltage/Frequency440VAC/50Hz, 3 phase 4 wire
Max Rated power

Resistive Power: 510kW

Reactive Power: 510kvar

Load Resolution

Resistive Load: 0.1.0.20.5.1.2.2.5.10.20.20.50.100.100.200KW

Reactive load:0.1.0.20.5.1.2.2.5.10.20.20.50.100.100.200kvar

PF(Power Factor)0.7-1
Load Tolerance (each step)±5%
Load Tolerance(overall)±3%
Display Precision0.5 class
Control Power380VAC/50Hz,
Wire Connection

Load power supply input——Copper bar (star coupling)

Control power supply input——Connector-bar

Communication InterfaceRS485,
Casing Dimensions and Coolingabout 1460*1980*1800mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling
WeightAbout 20000kgs/set


Product Advantage


1. Over-heat protection: Automatic load dump and give alarm when temperature is over safety thresholds.

2. Short Circuit Protection: Fuse could avoids damage to equipment when short circuit or current overload.

3. Fan protection: Machine could not do load testing before working power of fan is on.

4. The machine will unload and give alarm when any fan is abnormal or with insufficient air volume, etc.


Application

Motor manufacturing: The load bank is an ideal test equipment for generator power ,the frequency,the voltage,the current,power factor and other generator parameters.Most of the generator use the diesel oil,which can cause the fuel oil unfilled,carbon deposition ,complete machine efficiency reduced when the diesel oil load is lower than 50% or in idling situation for a long time and even cause starting difficulty ,power insuffciency,oil consumption increased,finally,opening the cylinder for maintenance too early and the abandonment ,so the load bank will be generator's ideal false load.