Testing on Generator Sets 11VAC 14700kw Dummy Generator Load Bank
Product Description
The system can accurately test the output power and load capacity
of various generator sets.The system consists of two parts of
measurement and loading, including AC load bank, data acquisition
system, automatic load and drop control system, cooling device,
auxiliary control,PC software,and so on.The user can freely select
local control or software control to operate the load bank.
Technical Parameter
Rating Voltage/Frequency | 11kVAC/60Hz, 3 phase 4 wire |
Rated Load Power | Resistive load: 14700kW |
Installed Capacity | Resistive load: 14700kW |
Load Step | Resistive load: 30 steps, 200kW×1, 500KW×29, min step load: 500KW |
PF(Power Factor) | 1 |
Load Tolerance(each step) | ±5% |
Load Tolerance(overall) | ±3% |
Display Precision | 0.5 class |
Control Power | 3 phase 4 wire 380V/50Hz |
Wire Connection | Load power supply input——Copper bar (star coupling) |
Communication Interface | RS485, RS232 |
Insulation | F |
Max Protection Grade | IP54 |
Way of Working | Continuous Work |
Cooling | Forced air cooling,Horizontal inlet air,Vertical cooling |
Casing Structure | Container, with a ladder, air inlet and outlet with mesh enclosure and protection door |
Transportation | Hoisting, there are lifting lug in top of casing |
Casing Color | Grey(RAL7035)or as per customer’s requirement |
Dimension | 3 container of 6058 mm×2438mm×2591mm(length*width*height) |
Weight | About 9000kg |
Workplace | Outdoor |
Ambient Temperature | -10℃~+50℃ |
Relative Humidity | ≤95% |
Altitude | ≤2500 meter |
Product Advantages
1. High Efficiency Data Management: display real-time testing data,
generate form, curve graph or report automatically, also can put
data into storage. According to generator set No. set up testing
file, support to query at any time, and improve data management
efficiency.
2. Comprehensive Protection Function: multiple protection, like
over temperature, smoke. When in danger, automatically terminate
the test and give alarm to protect safety of personnel and
equipment.
3. Stable Running: with the latest generation control module as the
core, a sharp rise in system response speed and anti-interference
performance, avoid function failure in complex electrical
environment, and ensure system running stably and reliably.
Application
Manufacturers of small gas engines also use load banks to test
newly manufactured engines under various mechanical loads. This is
accomplished by connecting the engine to the load bank via a device
called a dynamometer. Again, engine performance is monitored and,
if necessary, adjustments are made to ensure the product performs
within intended specifications