220 V 5 KW Rack Mounted Load Bank Black Surface With Forced Air Cooling

Brand Name:KaiXiang
Certification:ISO9001-2008
Model Number:AC220-5kW
Minimum Order Quantity:1 set
Delivery Time:Within 30 Working Days
Place of Origin:China
Contact Now

Add to Cart

Active Member
Location: Shijiazhuang Hebei China
Address: No33 Wangshan Road, Green Island Economic Development Zone, Shijiazhuang, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

220V 5kW Rack Mounted Load Bank With high performance and Black Surface

Introduction

5kW Rack Mount Load Bank for Data Center

When you build a data center, any unexpected glitch during commissioning can cause serious project delays, wasted productivity, and significant budget overruns. So integrating rack mounted load banks into the design phase can help our data center clients keep projects on budget and on time.

Application

(1) This unit specially designed for data center, it’s safe, reliable, small volume and can simulate the on-site server load.(2)Constant power.

(2) The diagram in the agreement is only for reference, specific please in kind prevail.

Parameters


System Parameter
Rating voltage/frequencySingle phase 220VAC/50Hz
Max Load PowerResisitive Power: 5KW
Load ResolutionResistive Load: 0.5kW,1kW,1kW,1kW,1.5kW
Power Factor1
Load Tolerance+(0-10%)
Insulation GradeGrade F
Way of WorkingContinuous Working
CoolingForced air cooling, intake air in front and exhaust cooling in back
Case ColorBlack
Case DimensionAbout 483mm*401mm*177.8mm(L×W×H)
WeightAbout 13kgs
Working Environment Parameter
Ambient Temperature-10℃~+40℃
Relative Humidity≤95%
Altitude≤2500 meters
Atmospheric Pressure86~106kPa
Brands of Main Components
Gear SwitchABB

Main Functions

5kW Rack Mounted Load Bank for Data Center

(1) Load Test: User can load any power within rated power, and test the output capacity of under test power supply.

(2) Control Mode: The laod bank is with 3 gear switches, can control loading/unloading by 3 ABB air switches.

(3) Fan Power Supply: Fan is installed near the air outlet, and powered on A loop socket. Please give priority to the use A loop when using this load bank, the fan start after A loop is connected to power supply, then can load/unload through 3 gear air switches combination.

(4) Temperature Protection: There will be sound and light alarm when the load bank temperature exceeds the safety threshold value.

(5) Load bank Cable: The internal cable adopts multi core flame retardant flexible cord, and with glass fiber casing protection