AC400V-1250kvA Adjustable Load Bank With Frequency 60 HZ In High Performance
Introduction
Adjustable Load banks can be supplied for most powers, voltages, frequencies and sizes. Multi-voltage load banks are also available for operation over a large voltage range. At the same time, It can operate in parallel with more than two units.
AC400V-1250kvA Adjustable Load Bank can simulate the real working conditions and provides a rigorous test regime for power supplies from 1kW to 60MW. Resistive, inductive(reactive),capacitive or combined load banks can be customised for any application.
Triumph load are available in stationary type for permanent installation or portable type with fork lift pocket base, castors. Larger load banks, typically above 1200kVA, are based on an ISO container construction. Special finishes including custom paint colors and stainless steel casings can be supplied.
Application
1. factory testing of engine generator sets
2. To reducewet stacking problems
3. Periodic excercising of stand-by engine generator sets
4. Ups system testing
5. Battery system testing
6.Load optimization in prime power applications
7. Factory testing of turbines
Technical specification
System Parameter | |
Rating voltage/frequency | 400V, 3 phase 4 wire 60Hz |
Max Load Power | Apparent Power: 1250KVA Resistive Load: 1000kW Inductive Load: 750KVAR |
Load Resolution | Resistive Load: 13 steps 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW,200kW,200kW,200kW, 200kW Inductive Load: 13 steps 1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 50KVAR, 100KVAR,100KVAR,200KVAR,200KVAR |
Power Factor | 0.8(lag) |
Load Tolerance (each step) | ±5% |
Load Tolerance (overall) | ±3% |
Fan &Control Voltage | External AC 3 phase 4 line, 400V/50Hz |
Wire Connection | Load bank input——Copper bar (star coupling ”Y”) Control power input——Connector-bar |
Communication Interface | RS485,RS232 |
Insulation | F |
Max Protection Grade | IP54 |
Duty Cycle | Continuous |
Cooling | Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling |
Enclosure | Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door |
Internal Lighting | Adequate internal lighting will be provided |
Transportation | Hoisting, there are lifting lug in top of casing |
Color | Grey RAL7035 or as required |
Dimensions | 4000mm×2350mm×2591mm(L×W×H) |
Operating Environment Parameter | |
Workplace | Outdoor |
Ambient Temperature | -10℃~+50℃ |
Relative Humidity | ≤95% |
Atmospheric Pressure | 86~106kPa |
Brands of Main Components | |
Contactor | Schneider |
Fuse | Miro |
PLC | Siemens |
Alloy Resistor | Kaixiang |
Data Processing Software | Kaixiang |
2. Users can set adjustable discharge power according to capability parameter and test request.
3. Voltage and current value can be displayed with multi-functional digital meter.
4. AC load bank is of all kinds of specifications and series, and include resistance, inductive and capacitive load.
5. Two or more Intelligent AC Load Bank can operate in parallel.