Professional Design Medium Voltage Capacitor Bank 2000KW For Generator Testing

Brand Name:KAIXIANG
Certification:ISO9001
Model Number:AC20-2200KW
Minimum Order Quantity:ONE SET
Delivery Time:ONE MONTH AFTER GET DEPOSIT
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram,
Contact Now

Add to Cart

Active Member
Location: Shijiazhuang Hebei China
Address: No33 Wangshan Road, Green Island Economic Development Zone, Shijiazhuang, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

ProFessional Design And Produce 2000KW Dummy Load For Generator Testing


Product Description


1.AC Load Bank offers the most robust, high-capacity designs in the industry.

2.It is setting the standard with intelligent operator controls, safety indication layouts, adjustable load step resolution, and lightweight designs.

3.AC Load Bank is the perfect solution for regularly scheduled maintenance testing and commissioning of mission-critical standby emergency power systems.


Technical Parameters


Rating Voltage/Frequency20kV/50Hz, 3 phase 3 wire
Rated power2000kw
Load Resolution400KW.800KW.800KW
PF(Power Factor)1
Load Tolerance (each step)±5%
Load Tolerance(overall)±3%
Display Precision0.5 class
Control Power380VAC/50Hz,
WeightAbout 15000kgs/set
Wire Connection

Load power supply input——Copper bar (star coupling)

Control power supply input——Connector-bar

Size9150*2438*2591mm

Technology Advantages

System can load power in rated range, measure generator steady-state 3 phase voltage, current, active power, power factor, frequency, and running time, and simulate the generator set, UPS real load working state. Power input using sectional type, energy dissipation type load, forced-air cooling, 3 phase fan decentralized supply air, air-flow is sufficient and low noise


Application


Motor manufacturing: The load bank is an ideal test equipment for generator power ,the frequency,the voltage,the current,power factor and other generator parameters.Most of the generator use the diesel oil,which can cause the fuel oil unfilled,carbon deposition ,complete machine efficiency reduced when the diesel oil load is lower than 50% or in idling situation for a long time and even cause starting difficulty ,power insuffciency,oil consumption increased,finally,opening the cylinder for maintenance too early and the abandonment ,so the load bank will be generator's ideal false load.



China Professional Design Medium Voltage Capacitor Bank 2000KW For Generator Testing supplier