Add to Cart
Professional Design And Produce 100kw Generator Resistive Load Bank
Product Description
1. load bank can accurately test the output power and load capacity
of various generator sets
2.the system consists of two parts of measurement and loading,
including AC load bank, data acquisition system, automatic load and
drop control system, cooling device, auxiliary control,PC
software,and so on.
3.The user can freely select local control or software control to
operate the load bank.
Technical Parameters
Rating Voltage/Frequency | 400VAC/50Hz, 3 phase 4 wire, |
Rated Load Power | Resistive load: 100kW |
Installed Capacity | Resistive load: 100kW |
Load Step | 1,2,2,5,10,10,20,50kW, min step load: 1kW |
PF(Power Factor) | 1 |
Load Tolerance (each step) | ±5% |
Load Tolerance(overall) | ±3% |
Display Precision | 0.5 class |
Control Power | 220VAC/50Hz, single phase |
Wire Connection | Load power supply input——terminal block |
Insulation | F |
Duty Cycle | Continuous |
Casing Dimensions and Cooling | about 860*570*710mm (length*width*height) Forced air cooling,Horizontal inlet air,Horizontal outlet air |
Weight | About 120kgs/set |
Transportation | Hoisting, there are lifting lug in top of casing |
Casing Color | Grey(RAL7035) |
Ambient Temperature | -10℃~+50℃ |
Relative Humidity | ≤95% |
Altitude | ≤1500 meter |
Atmospheric Pressure | 86~106kPa |
Contactor | Schneider |
Fuse | DELIXI |
MCU | INFINEON |
Data processing software | Kaixiang(self-developed) |
Alloy Resistance | Kaixiang(self-developed) |
Product Advantage
The system can be used with a computer to realize the intelligent
control, automatically completing the special test to all
electrical parameters of generating set and generating tables,
graphs, and supporting the print, comprehensively from the
cumbersome manual operation to provide scientific and efficient
detection means for the power generating sets.
Application
Motor manufacturing: The load bank is an ideal test equipment for
generator power ,the frequency,the voltage,the current,power factor
and other generator parameters.Most of the generator use the diesel
oil,which can cause the fuel oil unfilled,carbon deposition
,complete machine efficiency reduced when the diesel oil load is
lower than 50% or in idling situation for a long time and even
cause starting difficulty ,power insuffciency,oil consumption
increased,finally,opening the cylinder for maintenance too early
and the abandonment ,so the load bank will be generator's ideal
false load