Add to Cart
To make discharged lubricated oil from compressor to total oil free in class 0
Through the process of catalytic oxidation, Rotorcomp ETC converters actively transform the oil and hydrocarbons in
compressed air into water and CO2. ETC Converter continuously
supplies Class 0 compressed air, in accordance with ISO 8573-1,
with a residual oil content of < 0.0025 mg/Nm3 as well as an
oilfree condensate.
With its catalytic technology for the treatment of compressed air,
ETC provides a technical solution that has been successfully used
for many years in the automotive and chemical industries.
For compressed air upstream of a converter that has an oil content
of max. 200 mg/Nm3, ROTORCOMP guarantees oil-free Class 0
compressed air downstream of the converter.
In contrast to conventional filter systems (e.g., activated
carbon), the air quality is constantly maintained. Saturation and
the risk of a breakthrough by hydrocarbon compounds are reliably
prevented.
In contrast to oil-free compressors, the compressed air quality
does not depend upon the hydrocarbon content of the ambient air.
The operation of the catalytic converter is independent of the
temperature and humidity of the compressed air to be treated.
1. Guaranteed oil-free compressed air in accordance with ISO8573-1 Class 0 (residual oil content ≤ 0.0025 mg/Nm3), confirmed by independent TUV measurements.
2. Absolutely secure system since a protective shutdown unit
prevents oil-containing compressed air from entering into the
network in the event of a malfunction.
3. Guarantee on the operation of the catalyst for 5 years for
hydrocarbon concentrations at the ETCR inlet of up 200 mg/Nm3.
4. Lower energy consumption to a max. of 0.01 kWh/m3 through
Improved insulation of converter and housing.
5. Minimizes significant the bacteria, fungus and microbial
diversity content in the compressed air.
6. Pure and neutral condensate (Öl < 2mg/l; pH-Wert: 6 –7) after
ETC.
7. Irreversible separation of silicon monomeres out of the
compressed air.
8. Partial load capacity of 20 to 110 % of the nominal flow rate
when using the optional VS module.
9. Increased service life for downstream dryer.
ETC-SV Technical Data:
Model | Air flow @7bar | Max. Pressure | Pipe Diameter | Weight | Dimension(L*W*H) | Specific energy consumption during operation | Energy consumption @ normal flow | Installed power |
N³/min | Bar | MM | kg | mm | Kwh/N³ | kwh | kw | |
ETC-SV04 | 0.4 | 16 | 15*1.5 | 80 | 700*340*1400 | 0.009 | 0.2 | 1 |
ETC-SV1 | 1 | 16 | 18*1.5 | 140 | 860*455*1455 | 0.009 | 0.5 | 1.2 |
ETC-SV2 | 2 | 16 | 28*2 | 160 | 860*455*1655 | 0.009 | 1.1 | 2.5 |
ETC-SV5 | 5 | 16 | 35*2 | 360 | 1175*620*1890 | 0.007 | 2.1 | 5 |
ETC-SV7 | 7 | 16 | 42*2 | 410 | 1175*620*1890 | 0.006 | 2.5 | 5 |
ETC-SV10 | 10 | 16 | 42*2 | 590 | 1630*615*2100 | 0.005 | 3.0 | 10 |
ETC-SV15 | 15 | 16 | DN50 | 770 | 1630*880*2100 | 0.005 | 4.5 | 10 |
ETC-SV20 | 20 | 16 | DN65 | 900 | 1900*1140*2150 | 0.005 | 6.0 | 15 |
ETC-SV30 | 30 | 16 | DN65 | 1100 | 1900*1140*2150 | 0.005 | 9.0 | 21 |
ETC-S40 | 40 | 16 | DN80 | 1500 | 2200*900*2240 | 0.005 | 12.0 | 28 |
ETC-S50 | 50 | 16 | DN100 | 1700 | 2250*900*2240 | 0.005 | 15.0 | 28 |