Product Description:
The modular operating room operating room adopts air cleaning
technology to control microbial pollution sources to different
degrees to achieve the requirements of air cleanliness in the
controlled space environment suitable for various operations; and
provide suitable temperature and humidity to create a fresh, clean,
A comfortable operating environment with a low bacterial count
allows patients to suffer as little damage as possible during
surgery, and greatly reduces the rate of secondary infections of
patients and medical staff, especially intracranial surgery and
burn surgery, to ensure the patient's postoperative performance
Faster and better recovery, etc.
CURRENT MAIN REQUIREMENTS FOR LTF CEILING SYSTEMS
Reduction of the germ load of indoor air Surgical smoke removal in
the protected area Occupational safety and protection of the
surgical staff Compliance with the required air cleanliness class
in the protected area Discharge of cooling loads Maintenance of the
required room pressure (protective pressure maintenance) Compliance
with the ventilation comfort parameters such as air speed,
temperature, degree of turbulence, humidity and sound pressure
level Adherence to the defined illuminance of the priming
illumination in LTF ceilings Complete ceiling solution for
jointless connection to the rest of the ceiling and integration of
the room lighting and optionally the ceiling pendants or media
bridges The effectiveness and functionality of LTF ceiling systems
have meanwhile been proved by numerous studies and confirmed by
independent hospital hygiene committees!
Modular Operation Room Classification
(1) Class I operating room: the sterile clean operating room, which
mainly accepts operations such as brain, heart, and organ
transplants.
(2) Class II operating room: the sterile operating room, which
mainly accepts aseptic operations such as splenectomy, open
reduction of closed fractures, intraocular surgery, and
thyroidectomy.
(3) Class III operating room: that is, the operating room with
bacteria, which accepts operations on stomach, gallbladder,
liver,appendix, kidney, lung and other parts.
(4) Category IV operating room: the infection operating room, which
mainly accepts surgery for appendix perforation,
peritonitis,tuberculous abscess, abscess incision and drainage.
(5) Category V operating room: the special infection operating
room, which mainly accepts the operation of Pseudomonas aeruginosa,
gangrene bacillus, tetanus and other infections.
According to different specialties, the operating rooms can be
divided into general surgery, orthopedics, obstetrics and
gynecology, brain surgery, cardiothoracic surgery, urology, burns,
and ENT surgery.
Modular Operating Room Grade Standard
Cleanliness | Maximum average concentration ofbacteria by sedimentation
method(plankton method) | Air cleanliness level | Reference surgery |
Cleanliness | Operation Area | Referencesurgery | Aroundarea | Reference surgery |
I | 0.2cfu/30minp90 (5cfu/m3) | 0.4 cfu /30min p90 (10cfu/m3) | 5 | 6 | Prosthesis implants.certain large organtransplants, surgical
siteinfections can directlyendanger life and qualityof life and other operations |
II | 0.75cfu/30minp90 (25cfu/m3) | 1.5cfu/30minp90 (50cfu/m3) | 6 | 7 | Major surgery involvingdeep tissues and majororgans of life |
III | 2.0cfu/30minp90 (75cfu/m3) | 4.0cfu/30minp90 (150cfu/m3) | 7 | 8 | Other surgicalprocedures |
IV | 6. 0cfu/30min p90 | 8.5 | Infection and severecontamination surgery |
Technical Parameters:
Parameter | Value |
---|
Size | Customized |
Storage Temperature | 0-50°C |
Warranty | 1 Year |
Material | Antibacterial Electrolytic Plate |
Product Type | Class 10000 Modular Operation Theatre Project, Hospital Operating
Room |
Power Source | Electric |
Usage | Hospital |
Color | Customized |
Weight | 1500KG |
Operating Temperature | 0-40°C |
Applications:
The Yaning YN-OTR Modular Operating Room is a Class 10000 modular operation theatre project designed to
meet the needs of hospitals. It is manufactured in China, and carries a CE certification, ensuring that it meets safety and quality
standards. The minimum order quantity for this product is 1 SET, and the price is 15000USD/SET. It is packaged in a wooden box, and delivery time is typically 15-25 days. Payment terms include EXW/FOB/CIF, and the supply ability is up to 100 sets/month. The power source of the system is electric, and its storage temperature is between 0-50°C. The total weight of the unit is 1500KG, and it is designed for use in hospitals. It is an ideal solution for any facility that requires a modular operating room.
FAQ:
1. How can we guarantee quality?
Always a pre-production sample before mass production;
Always do final test and inspection before shipment;
2.What can you buy from us?
1) Air Purification equipment like Air Shower, Pass Box, FFU, BFU,
Clean Bench, Clean Booth, etc
2) Operating Room Supporting Equipment, like Quick-install
operating room, Stainless steel cabinets, Laminar Flow Ceiling,
Socket box for OT room, OT room intelligence Panel, Scrub sink, all
kinds of hermetic doors, operating room etc
3) Air Filter, such as Plate pre filter, F5-F9 Medium Pocket
Filter, V-bank HEPA Filter, Pleated HEPA Filter, Activated carbon
filter, Gel Seal HEPA Filter, and High Temperature Resistant HEPA
Filter etc.
4) Air Conditioning and Ventilation Terminal Equipment: Air Vent
Louver Grille Series and Regulating Valve and Fire Damper
3. Why should you buy from us not from other suppliers?
YANING brand clean room equipment:air shower pass box,clean
bench,FFU,softwall clean room YANING brand Air
filters:HEPA,pre-filter,pocket filter,V type filter all passed
ISO14001,ISO9001,TUV,ROHS.CE,UL test.
Best price and service,each product will follow strict facty test.
4. What services can we provide?
Quality guarantee for core components for 1 year
Online technical support for assembly and after-sales service
Language Spoken:English and Chinese
5. What's our payment term?
50% deposit after PI confirmed and 50% balance TT in advance before
shipment