

Add to Cart
High Specificity Canine Vasoactive Intestinal Peptide ELISA Kit VIP
Sandwich ELISA Kit Customized
Cat.No E0290Ca
Standard Curve Range: 2ng/L - 700ng/L
Sensitivity: 1.53ng/L
Size: 96 wells
*This product is for research use only, not for use in diagnosis
procedures. It’s highly recommend to read this instruction entirely
before use.
Precision
Intra-Assay Precision (Precision within an assay) Three samples of
known concentration were tested on one plate to assess intra-assay
precision.
Inter-Assay Precision (Precision between assays) Three samples of
known concentration were tested in separate assays to assess
inter-assay precision.
CV(%) = SD/mean x 100
Intra-Assay: CV<8%
Inter-Assay: CV<10%
Assay Procedure
1. Prepare all reagents, standard solutions and samples as
instructed. Bring all reagents to room temperature before use. The
assay is performed at room temperature.
2. Determine the number of strips required for the assay. Insert
the strips in the frames for use. The unused strips should be
stored at 2-8°C.
3. Add 50μl standard to standard well. Note: Don’t add antibody to standard well because the standard solution
contains biotinylated antibody.
4. Add 40μl sample to sample wells and then add 10μl anti-VIP
antibody to sample wells, then add 50μl streptavidin-HRP to sample
wells and standard wells ( Not blank control well ). Mix well.
Cover the plate with a sealer. Incubate 60 minutes at 37°C.
5. Remove the sealer and wash the plate 5 times with wash buffer.
Soak wells with at least 0.35 ml wash buffer for 30 seconds to 1
minute for each wash. For automated washing, aspirate all wells and
wash 5 times with wash buffer, overfilling wells with wash buffer.
Blot the plate onto paper towels or other absorbent material.
6. Add 50μl substrate solution A to each well and then add 50μl
substrate solution B to each well. Incubate plate covered with a
new sealer for 10 minutes at 37°C in the dark.
7. Add 50μl Stop Solution to each well, the blue color will change
into yellow immediately.
8. Determine the optical density (OD value) of each well
immediately using a microplate reader set to 450 nm within 10
minuets after adding the stop solution.
Reagent Provided
Components | Quantity |
Standard Solution (800ng/L) | 0.5ml x1 |
Pre-coated ELISA Plate | 12 * 8 well strips x1 |
Standard Diluent | 3ml x1 |
Streptavidin-HRP | 6ml x1 |
Stop Solution | 6ml x1 |
Substrate Solution A | 6ml x1 |
Substrate Solution B | 6ml x1 |
Wash Buffer Concentrate (25x) | 20ml x1 |
Biotinylated Canine VIP Antibody | 1ml x1 |
User Instruction | 1 |
Plate Sealer | 2 pics |
Zipper bag | 1 pic |
Precautions
Specimen Collection
Serum Allow serum to clot for 10-20 minutes at room temperature.
Centrifuge at 2000-3000 RPM for 20 minutes.
Plasma Collect plasma using EDTA or heparin as an anticoagulant.
Centrifuge samples for 15 minutes at 2000-3000 RPM at 2 - 8°C
within 30 minutes of collection.
Urine Collect by sterile tube. Centrifuge at 2000-3000 RPM for
approximately 20 minutes. When collecting pleuroperitoneal fluid
and cerebrospinal fluid, please follow the procedures
above-mentioned.
Cell Culture Supernatant Collect by sterile tubes when examining secrete components.
Centrifuge at 2000-3000 RPM for approximately 20 minutes. Collect
the supernatants carefully. When examining the components within
the cell, use PBS (pH 7.2-7.4) to dilute cell suspension to the
cell concentration of approximately 1 million/ml. Damage cells
through repeated freeze-thaw cycles to let out the inside
components. Centrifuge at 2000-3000 RPM for approximately 20
minutes.
Tissue other body fluids Rinse tissues in PBS (pH 7.4) to remove excess blood thoroughly
and weigh before homogenization. Mince tissues and homogenize them
in PBS (pH7.4) with a glass homogenizer on ice. Thaw at 2-8°C or
freeze at -20°C. Centrifuge at 2000-3000 RPM for approximately 20
minutes.
*Sample can't be diluted with this kit. Owing to the the material we use to prepare the kit, the sample
matrix interference may falsely depress the specificity and
accuracy of the assay.
Summary
1. Prepare all reagents, samples and standards.
2. Add sample and ELISA reagent into each well. Incubate for 1 hour
at 37°C.
3. Wash the plate 5 times.
4. Add substrate solution A and B. Incubate for 10 minutes at 37°C.
5. Add stop solution and color develops.
6. Read the OD value within 10 minutes.
Calculation of Result
Construct a standard curve by plotting the average OD for each
standard on the vertical (Y) axis against the concentration on the
horizontal (X) axis and draw a best fit curve through the points on
the graph. These calculations can be best performed with
computer-based curve-fitting software and the best fit line can be
determined by regression analysis.