3 Phase Testing Equipment , Energy Meter Calibration Equipment Automatic Range Switching

Brand Name:KRE
Certification:ISO9000
Model Number:KE9302
Minimum Order Quantity:1 piece
Delivery Time:30 days
Payment Terms:T/T, D/P, D/A, L/C, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Rm 210,No 69 Guangpu Rd(W), Huangpu Dist. Guangzhou, 510663 CHINA
Supplier`s last login times: within 37 hours
Product Details Company Profile
Product Details

Three Phase Reference Standard Meter high precision wide current range accuracy 0.05

KE9302 Three Phase Reference Standard Meter


KE9302 is three phase reference standard meter which can be used as the power standard for the electric power departments, meter manufacturer and metrology laboratory.

KE9302 has 2 specifications for different occasions:

  1. KE9302A has error calculation system inside and can test the error of MUT through pulse input terminal.
  2. KE9302B has no error calculation system and it is applied to the occasion where the external side has already had the error calculation system. ( For example, the energy meter test system)

Product highlights:

  1. High precision, measuring error of three phase power and electric energy error ≤±0.05%
  2. Automatic range switching
  3. 6 channel ADC for signal sample
  4. Pulse input and output in both front and back panel, convenient for use
  5. 7 inch color LCD to display abundant info
  6. Harmonic measurement, can test up to 59th harmonic, and displaying Columnar Section.
  7. Energy constant can be set by user
  8. Build-in IPC to control and manage the instrument
  9. External mouse and keyboard can be used for connection
  10. Error calculator can deal with 2 channel pulse input signal at the same time
  11. Multi-parameter measurement, testing three phase voltage, current, power, electric energy, power factor, phase and frequency synchronously
  12. Multi-mode measurement: 3P4W,3P3W, 1P2W, active or reactive
  13. Display waveform and vector diagram
  14. It has dual communication port RS232 and Ethernet

Main functions:

  • Normal measurement:

Voltage (P-N), voltage (P-P)

Current
Phase angle (U-U), phase angle (U-I)
Power factor
Frequency

  • Active power, reactive power and apparent power
  • Total of active power, reactive power
  • Total of power factor
  • Waveform disply
  • Vector diagram display
  • Harmonic analysis
  • Dial test (energy accumulation test)
  • Error test

Technical parameters:


Voltage measurement

Voltage range

10V – 500V

Accuracy

±0.05% (40V – 500V)

Harmonics

2nd- 59st

Current measurement

Current range

1mA – 120A

Accuracy

±0.05% (0.01A – 120A)

Harmonics

2nd- 59st

Power measurement

(accuracy)

Active power

±0.05% (0.01A – 120A)

Reactive power

±0.05% (0.01A – 120A)

Apparent power

±0.05% (0.01A – 120A)

Energy measurement

(accuracy)

Active energy

±0.05% (0.01A – 121A)

Reactive energy

±0.05% (0.01A – 122A)

Apparent energy

±0.05% (0.01A – 123A)

Phase measurement

Phase range

0° -- 360°

Accuracy

±0.001°

Frequency measurement

45Hz-65Hz

45Hz-- 65Hz

±0.001Hz

±0.001Hz

Pulse output

High frequency output(CH)

Defined by users

Low frequency output(CH)

CH / 10000

Output channel

3

Pulse input

Input channel

4

Input frequency

Max. 1MHz

Others

Power supply

220V±10% 50/60Hz±2Hz

Temperature

-10°C -- +40°C

Humidity

45% -- 75%RH

Dimension

445mm×139mm×310mm

Weight

8kg



China 3 Phase Testing Equipment , Energy Meter Calibration Equipment  Automatic Range Switching supplier

3 Phase Testing Equipment , Energy Meter Calibration Equipment Automatic Range Switching

Inquiry Cart 0