Floor Heating HVAC Programmable Radiator Thermostat With Digital Temperature Controller
Weekly circulation, it is possible to set 6 periods called events
each day with different temperatures, also you can select "manual
mode" or "temporary control mode" according to your individual
requirements. The thermostat is recommended for the control of
electric heating devices or on/off valve actuator used in
water-based heating systems.
Technical data
Power Supply | AC200-240VAC 50/60HZ |
Accuracy | ±0.5ºC |
Probe sensor | NTC Sensor |
Power Consumption | <1W |
Load current | 3A(water heating),16A(electric heating) |
Temperature Adjustable Range | 5°C~90°C( can adjust to 35°C~90°C) |
Limit Temperature Range | 5°C~60°C( factory setting: 35°C) |
Output | Switch relay |
Insulating condition | Normal environment |
Running program | Set per 1 week as a cycle |
Installation | Wall mounted |
Application | Water Floor Heating System |
Electric Floor Heating System | |
Infrared Heater System | |
Certificate | CE,RoHS |
Advanced setting (qualified person preferred)
When the thermostat is turned off, You can press"Menu" and turn on
it at the same time ,then you can enter the mode of advanced
setting.
Symbol | Setting | Up or Down | |
1 | ADJ | Temperature calibration | Adjust measured temperature |
2 | SEN | Sensor mode | IN: built-in sensor |
3. | LIT | Limitation temperature | Adjust limitation value, |
4 | DIF | Switching | Adjust switching differential |
5 | LTP | Antifreeze function | Turn on/off Anti-frozen function |
6 | PRG | Set vacation mode | 00: 5/2 day mode 01: 6/1 day mode |
7 | RLE | Potential- free output and main power output in the same/different way | Change the present linkage way |
8 | DLY | Delay time of Potential- free output | Change linkage delay time |
9 | HIT | Max temperature | Limitation temperature setpoint |
AFAC | Reset to factory settings | Press""and hold for 5s,all parameters will be reset |