Add to Cart
Underfloor heating wall thermostats floor heating thermostat
controller with touch screen
Touch Screen Period Programming Thermostat Weekly circulation, it
is possible to set 6 periods called events each day with
corresponding pre-set temperatures, also you can select "period
control mode" or "manual mode" according to your individual
requirements.
The SK82 series Touch Screen Thermostat has been developed to
control electric underfloor . These units are designed for use in
commercial, industrial, civil and domestic properties.
Now you don't need to choose between saving money or staying
comfortable. The thermostat can help you save up energy costs every
year when you use a pre-set heating program schedule. When you use
our intuitive mobile app, you can adjust your room thermostat
schedule around your life, so you're not needlessly heating an
empty home.
Technical data
Power Supply | AC200-240VAC 50/60HZ |
Accuracy | ±0.5ºC |
Probe sensor | NTC |
Power Consumption | <0.3W |
Load current | 3A(water heating),16A(electric heating) |
Temperature Adjustable Range | 5°C~60°C( can adjust to 35°C~60°C) |
Limit Temperature Range | 5°C~60°C( factory setting: 35°C) |
Output | Switch relay |
Insulating condition | Normal environment |
Running program | Set per 1 week as a cycle |
Installation | Wall mounted |
Application | Water Floor Heating System |
Electric Floor Heating System | |
Infrared Heater System | |
Certificate | CE,RoHS |
Advanced setting (qualified person preferred)
You can press "M" and"Time"and hold for 5 seconds at the same time
to enter the mode of advanced setting when the thermostat is turned
off. The following seven function can be chosen by pressing "M".
Symbol | Setting | Up or Down | |
1 | ADJ | Temperature calibration | Adjust measured temperature |
2 | SEN | Sensor mode | IN: built-in sensor |
3 | LIT | Limitation temperature | Adjust limitation value, |
4 | DIF | Switching differential | Adjust switching differential |
5 | LTP | Antifreeze function | Turn on/off Anti-frozen function |
6 | PRG | Set vacation mode | 2: 5/2 day mode |
7 | RLE | Potential-free output | 00: in same way |
8 | DLY | Potential-free output delay | Change the delay time |
9 | HIT | Max. Temperature | Max. Limitation temperature set point (99℃) |
10 | AFAC | Reset to factory settings | Programming parameters will be reset to factory settings when symbol "" appears |
Writing Diagram
Sensor failure
Please select the right sensor mode when operation, it will display
the "Err" symbol on screen far sensor failure, thermostat must be
checked till the fault is eliminated.
Packaging Details | UNIT WEIGHT: 0.35KG/PC; 64 PCS/CTN; GROSS WEIGHT: 22.4KG; PAPER BOX PACKING; BOX DIMENSION: 42*40*29CM |
---|---|
Delivery Detail | Shipped in 15 days after payment |