ASTM E648-19 Fire Testing Equipment Floor Covering Critical Radiant Flux Test

Brand Name:DAXIAN
Certification:ISO 9239-1 : 2002, ASTM E648-19ae1
Model Number:DX8401
Minimum Order Quantity:1 set
Delivery Time:30 days after order confirmed
Payment Terms:L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: No.168 Zhen'an West Road Changlian Industry Mansion Xiabian Community Dongguan China
Supplier`s last login times: within 28 hours
Product Details Company Profile
Product Details
ASTM E648-19 Fire Testing Equipment Floor Covering Critical Radiant Flux Test Machine

Scope of application:


- Suitable for testing with a small flame igniting a floor covering material that is placed horizontally and exposed to an inclined thermal radiation field.

- Suitable for all kinds of flooring materials. Such as: textile carpets, cork, wood plastic flooring and floor spraying materials. The device may reflect the burning properties of the flooring material including the substrate used, backing material, underlay material, or flooring material

- Measure and describe the properties of floorings in response to heat and flame under controlled laboratory conditions.


Standard:


ISO 9239-1:2002 :Reaction to fire tests for floorings- Part1: determination of the burning behaviour using a radiant heat source;

ASTM E648-19ae1: critical radiant flux of floor-covering systems using a radiant heat energy source.


Technical parameters:


Heat flux meter measurement range(0-15)Kw/m22
Smoke speed(2.5 ± 0.2) m/s
Smoke extraction capacity(39-85) m/min
Combustion gas flow(0.026±0.002)L/S
Flame height60-120mm adjustable
Combustion gaspropane. (prepared by customer)

1. This machine structure consists of a combustion box and a control box.

2. Heat flux meter accuracy: ±0.2Kw/m2;

3. Heat flux meter accuracy: <±3%;

4. Thermal radiation high temperature measurement range: 400-600 °C, accuracy is ± 0.5 °C;

5. Black body temperature error: ±5°CC;

6. Porous refractory radiant panel size: 300mm × 450mm, able to withstand about 900 °C high temperature;

7. Thermocouples: κ-type stainless steel armored thermocouples with a diameter of 3.2 mm;

8. Heat flux distribution requirements: at 200mm (9.1 ± 0.4) KW/m2; at 400mm: (5.0 ± 0.4) KW/m2;

9. At 600mm: (2.4 ± 0.2) KW/m;

10. Burning torch: 35mm 0.7mm hole in outer diameter g10mm inner diameter c6mm torch tube;

11. Ignition system: high voltage electronic ignition;

12. Burning box size: L1420*W1200*H2300(mm)


ItemLIst
1Test Chamber
2Radiant Heat Energy
Source
3Pyrometer
4Specimen
Holder
5Pilot Burner
6Thermocouples
7Exhaust System
8Dummy Specimen
9Heat Flux
Transducer
10Timing Device



China ASTM E648-19 Fire Testing Equipment Floor Covering Critical Radiant Flux Test supplier

ASTM E648-19 Fire Testing Equipment Floor Covering Critical Radiant Flux Test

Inquiry Cart 0