30kw 37.5kva Small Power 1500 Rpm Diesel Generator Three Phase Generator
Supply Ability
Supply Ability:
100 set per month Open Power Generating Sets With Fuel Tank , 3
Phase Diesel Engine Generator
Packaging & Delivery
Packaging Details
1. Plastic/ Wooden Case Packing for Open Power Generating Sets With
Fuel Tank , 3 Phase Diesel Engine Generator
2. as your requirement
Port
qingdao port
Lead Time : 30 work days
Parameter
1. Specification of genset | ||
Gensets model | BST-30GF | |
Prime power | 30kw | |
Rated Voltage | 400/230V | |
Rated frequency(HZ) | 50 | |
Rated Speed | 1500rpm | |
Power Factor | 0.8(lagging) | |
Dimensions(mm) (L×W×H) | 1700x800x1150mm | Open type |
Genset Weight(kg) | 1000 | |
2. Specification of diesel engine | ||
Engine brand | K4100D | |
Number of Cylinders | 4 | |
Bore×Stroke (mm×mm) | 100*115 | |
Cylinder arrangement | Vertical in-line | |
Cycle | Four stroke | |
Aspiration | Natural aspiration, Air/Water cooling | |
Cooling System | Forced Water Cooling Cycle | |
3. Specification of alternator | ||
Number of Phase | 3 | |
Connecting Type | 3 Phase and 4 Wires | |
Number of Bearing | 1 | |
Protection Grade | IP23 | |
Altitude | ≤1000m | |
Exciter Type | Brushless ,Self-exciting, AVR automatic voltage regulating,100% Copper winding wire (Brush is also available) | |
Insulation Class | H | |
Telephone Influence Factor (TIF) | ≤50 | |
THF | ≤2% | |
Voltage Regulation, Steady State | ≤±1% | |
Transient State Voltage | ≤-15%~+20% |
Diesel generator operation
1. Select the oil that meets the requirements of the generator.
Before starting the engine, check whether the oil level and cooling
level are normalLocation, continuous boot operation4Check the oil
level around the hour.
2. Choose the antifreeze or antirust solution approved by the
manufacturer according to the ambient temperature.Add after
adjusting to proportion;Don'tUse clean water only (rusting of
engine channel, cavitation erosion, rust of thermostat, etc.).Add
cooling fluid to generate electricityThe machine body exhausts air
to prevent damage to the cylinder in the channel
3. The unit is forbidden to work under overload.The unit is
strictly forbidden to be hit by large load.
4. Before the unit is shut down, load is discharged and no load is
operated3 ~ 5Stop after a minute.The unit is not allowed to operate
for a long time under low load or idle state.The spare unit should
be operated without load at least once a month.Empty vessels
carryingTurn time10to15Minutes;And the annual load (80%At least
operation2to4Hours.
5. The power supply of the reserve unit should be charged
regularly, and the electrolytic level of the battery should be
checked at the same time. If not enough, it should be added in time
(it can be steamedBoiling water).Check whether the connection of
the battery line is firm. Do not connect the wrong way.
6. Operating personnel carefully complete the unit's operation,
maintenance records.