Add to Cart
Deacription:
FHM2 Series Optical Multimeter'
OMC provides high precision optical multimeter. FHM2 Series Optical Multimeter integrates a stable optical laser source and a precise optical power meter.
The optical laser source unit launches the laser whose wavelengths are at 1310/1490/1550nm or 1310/1550nm (according to the model). The optical power meter unit can recognize the wavelength automatically. FHM2 Series Optical Multimeter offers a large storage capacity; With the assorted software, user can generate a report or manage the test report easily.
Features:
Type | FHM2A01 | FHM2B01 |
Power Meter Parameters: | ||
Calibration Wavelength | 850/1300/1310/1490/1550/1625nm | |
Connector | interchangeable FC/SC (ST optional) | |
Data Storage | 999 items | |
Ref.Value | Yes | |
Display Units | dB/dBm/mW/uW | |
Display Precision | 0.01dB | |
Accuracy | ±5%±1nW | |
Wavelength Recognition | 1310/1490/1550 (input power≥-40dBm) | |
Tone Detection | 270Hz/1KHz/2KHz (input power≥-40dBm) | |
Measuring Range | -70 to +10dBm | -50 to +26dBm |
Laser Source Parameters: | ||
Output Wavelength | 1310/1550nm | |
Connector | fixed FC/PC (interchangeable FC/SC/ST customized) | |
Modulation Frequencies | 270Hz/1KHz/2KHz | |
Output Power | -5dBm±0.5dB | |
Stability Long-term (8h) | ±0.1dB@1310/1550nm | |
Stability Short-term(15min) | ±0.05dB@1310/1550nm | |
Wavelength Recognizing Code | Yes | |
Auto Power off | Yes | |
General Parameters: | ||
Power Supply | 2pcs*NiHM 1.2V, 2000mAh; AC/DC Adapter | |
PC Interface | USB | |
Battery Life | >100 hours (laser off) | |
Storage Temperature | -20℃~+70℃ | |
Operating Temperature | -10℃~+50℃ | |
Relative Humidity | <90% (Non-condensing) |
Type | FHM2A02 | FHM2B02 |
Power Meter Parameters: | ||
Calibration Wavelength | 850/1300/1310/1490/1550/1625nm | |
Connector | interchangeable FC/SC (ST optional) | |
Data Storage | 999 items | |
Ref.Value | Yes | |
Display Units | dB/dBm/mW/uW | |
Display Precision | 0.01dB | |
Accuracy | ±5%±1nW | |
Wavelength Recognition | 1310/1490/1550 (input power≥-40dBm) | |
Tone Detection | 270Hz/1KHz/2KHz (input power≥-40dBm) | |
Measuring Range | -70 to +10dBm | -50 to +26dBm |
Laser Source Parameters: | ||
Output Wavelength | 1310/1490/1550nm | |
Connector | FC/PC, SC/PC | |
Modulation Frequencies | 270Hz/1KHz/2KHz | |
Output Power | 0dBm±0.5dB | |
Stability Long-term (8h) | ±0.1dB@1310/1550nm; ±0.2dB@1490nm | |
Stability Short-term(15min) | ±0.05dB@1310/1550nm; ±0.1dB@1490nm |
Wavelength Recognizing Code | Yes |
Auto Power off | Yes |
General Parameters: | |
Power Supply | 2pcs*NiHM 1.2V, 2000mAh; AC/DC Adaptor |
PC Interface | USB |
Battery Life | >100 hours (laser off) |
Storage Temperature | -20℃~+70℃ |
Operating Temperature | -10℃~+50℃ |
Relative Humidity | <90% (Non-condensing) |
Dimension | 168mmL×76mmW×43mmH |
Weight | 310g |
Standard Accessories: | |
FC adapter, SC adapter, 2*rechargeable batteries, AC/DC adapter,
3*ceramic sleeves, USB cable, | |
Optional Accessories: | |
ST adapter (model: N000500), 1.25mm PD adapter, 2.5mm PD adapter | |
Customization: | |
APC |