Add to Cart
Automatic Oil Pressure Switch / Mechanical Pressure Switch Relay Signal Alarm Type
Accuracy: The value of the accuracy of the device, including linearity, tolerances, hysteresis, repeatability, and so on.
Maximum pressure (Max.P): The maximum pressure range.
Full-Scale (F.S): The difference between the maximum and minimum values of the
pressure range.
Break difference (dead zone): It refers to the difference between the switch setting action
value and the reset value. For example, when the setting value is 1
MPa and the actual reset value is 0.9 MPa, the break difference is
0.1 MPa.
Operating temperature: It refers to the temperature range where the internal mechanism
and sensitive components of the instrument will not be deformed
continuously during operation. The recommended working temperature
range of the general pressure switch is -5~400C. If the medium
temperature is too high, consider adding an accessory siphon
(watering) to achieve the purpose of cooling.
♦ Features
-- 4 digital LED display pressure, Accuracy≤0.5%
-- Three pressure units available ( Psi, Kg/cm2 , Mpa)
-- Adjustable high & low pressure threshold and delay time
-- Adjustable control mode:normal control and reverse control
-- Pressure leak and loss protection,secure setting-up
-- Anti-electromagnetic interference design
-- Zero clearing with one button
♦ Protective Functions
● Upper limit alarm(high pressure)
● Lower limit alarm(low pressure)
● Pressure leak alarm
● Pressure loss alarm(no pressure)
♦ Typical Applications
• Machine Automation • Engineering Machinery
• Electromechanical Integration Equipment • Pump&compressor
• Hydraulic System • Medical project • Pipeline engineering
♦ Specification
Pressure range | General type:0~1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 60Mpa Micro type:0~0.2, 0.5Mpa Negative type: -0.1~0.1Mpa |
Pressure unit | MPa,kgf/cm2,PSI adjustable |
Overload pressure | 150% |
Accuracy grade | ±0.5%FS |
Power supply | 24VDC,220VAC,380VAC |
Alarm point | Full range can be set |
Alarm type | relay signal |
Load capacity | 380V 3A ,220V 5A ,24V 5A |
Sampling frequency | 10 times/sec |
Operating temperature | -20℃-80℃ |
Compensation Temperature | -10 ~60 ℃ |
Measurement medium | Gas, water, oil (compatible with 316 stainless steel) |
Electric protection | Short-circuit protection, reverse polarity protection, anti-electromagnetic interference design |
Pressure connector | M20*1.5 G1/2,G1/4 (other connector could be customized) |
Connector material | 304SS |
Optional module | RS485 Modbus Communication protocol |
Dial diameter | 100mm |
Shell material | 304SS |
Mounting methods | Axial direction or radial direction optional |
Weight | 0.6Kg |