Reactive Power Full Compensated 380v Resonant Test System For Generator

Brand Name:GDZX
Certification:ISO9001
Model Number:ZXGXZ
Minimum Order Quantity:1 Set
Delivery Time:7~10 work days
Payment Terms:L/C, D/A, D/P, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Wuhan Hubei China
Address: No.1 Fenghuangyuan Second Road, Jiangxia District, Wuhan City, Hubei Province, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Inductance Adjustable AC Voltage Withstand Resonant Test System for Generators High Voltage Test Equipment


Introduction

ZXGXZ Resonant test system for Generators require the use of power frequency voltage withstand voltage, the current national standard factory frequency voltage frequency defined as 45Hz ~ 65Hz, but in many test situations, requirements of generator is 50Hz plus or minus 2Hz ac testing, and generator stator winding of electric capacity is larger, the domestic most current test unit USES a resonant transformer to test it, but the resonant transformer itself is very heavy, field test is very inconvenient. Our company has designed and developed a frequency modulated induction generator ac compressive resonance device.


Features

1. As the resonant system is reactive power full compensated, the power of the equipment and power source is only less than 1/10 of measured equipment; with smaller volume and lighter weight compared with the equipment in same capacity. The device with large output capacity and small power supply capacity, low cost, easy to operate and safe.

2. Serial resonant system actually is current filter circuit, which make the tested equipment through current almost being fundamental current, the output voltage distortion (THD) is very small, better than current AC voltage withstand equipment.

3. The short circuit current after flash-over or breakdown is only less than 1/10 (1/Q) of the test current before the short-circuit, which can effectively prevent further damage to fault point after breakdown.

4. Auto blowout the arc after flash-over, which is a long and stable process to recover the serial resonant voltage, so it is very safe.


Technique parameter:

Rated output voltage≤0~60kV(AC effective value)
Output frequency50Hz
Resonant voltage waveformSine wave, distortion ≤1%
Working modeFull power continuous working time: 1min
Quality factor10~40
Maximum measured capacity≤3000kVA
Power supply380V±15%, frequency:50Hz

Serial product and application:

ModelApplication (AC voltage withstand test for generator with output voltage ≤20kV, frequency: 50Hz±2Hz)
Control cabinetReactorExcitation transformerDividerApplication
ZX-GXZ-100/5010kW/220V50kV/1A1010kW/5kV50kV/500pFGenerator 0.07~0.13uF
2 sets10kVcable(300mm2)≤1.0km
ZX-GXZ-150/5015kW/380V50kV/1.5A 2 sets15kW/5kVGenerator 0.13~2uF
10kVcable(300mm2)≤1.5km
ZX-GXZ-225/5025kW/380V50kV/1.5A 3 sets,25kW/5kVGenerator 0.2~0.27uF 10kVcable(300mm2)≤2.5km
ZX-GXZ-350/5030kW/380V60kV/2A 3 sets30kW/5kVGenerator 0.27~0.33uF

Note: solution to make according to the measured equipment.


Product Gallery


China Reactive Power Full Compensated 380v Resonant Test System For Generator supplier

Reactive Power Full Compensated 380v Resonant Test System For Generator

Inquiry Cart 0