Instructions for product use:
A. Place the cleaner horizontally on the ventilated and dry
workbench around, add clean water to the cleaning cylinder until 35
mm below the level of the cleaning cylinder, and then add a proper
amount of detergent or detergent.
B. Connect the power plug of the cleaning machine to a single-phase
220V, 10A power supply, which must be reliably grounded (three-hole
socket).
C. The left area of the machine control panel is the temperature
control area and the right area is the ultrasonic working time
control area. The specific operation is as follows.
D. Adjusting the working time of ultrasonic wave: After power is
connected, the time control knob on the right side is rotated
clockwise, and the working time value that needs cleaning can be
set. Loosen the knob, the machine will start countdown work
according to the set cleaning time. When the cleaning time reaches
the completion of the cleaning work, the machine can rotate the
timer knob repeatedly to set the working time when it does not cut
off the power supply, so that the machine can repeat the work for
the next cleaning.
E. Adjust the working temperature (heating if necessary). After
power supply is switched on, rotate the temperature setting knob on
the left side. If the temperature of the liquid in the tank is
lower than the setting value, the heating system will start to
work. When the setting value is lower than the actual temperature,
the operation will be invalid. When the heater works for a period
of time and the cleaning liquid temperature in the tank is heated
to a set temperature, the heating indicator lights out. The knob
can be set in the "OFF" position and the heating function can be
turned off (the heating function can not be turned on as far as
possible to protect the ultrasonic circuit).
F. Shut down after finishing the work: After cleaning, if you do
not need to operate again, you should first press the temperature
knob to turn to "OFF" and turn off the heating element. The
ultrasonic timer knob is placed in the "OFF" position, and the
machine will stop working. Turn off the power supply, wait for the
cleaning fluid to cool to room temperature, then pour out the
cleaning fluid, and wipe the machine clean.
APPLICATION RANGES:
DOMESTIC | |
Jewelry | Necklaces, rings, bracelets, earrings etc |
Watches and glasses | Waterproof wristwatches, watch chains, glasses, sunglasses etc |
Toiletry items | Electric toothbrush heads, electric shaver heads, razor blades, combs, toothbrushes, dentures etc |
Discs | CDs, DVDs, DVDs, CD-R discs, laserdisc etc |
Office equipment | Printed heads, fountain pen nibs, wax or rubber stamps , Calligraphic pens/ nibs etc |
Model | Tank Size | Unit Size | Volume | Power | Ultrasonic Frequency | Heating Power | Timer | Heating |
L x W x H(mm) | L x W x H(mm) | (L) | (W) | (KHz) | (W) | (MIN) | (℃) | |
ARS-XQXJ-103H | 150x140x65 | 190x170x185 | 1.3 | 50 | 40 | 100 | 1-99 | 0-80 |
ARS-XQXJ-002H | 150x140x100 | 190x170x220 | 2 | 50 | 100 | 1-99 | 0-80 | |
ARS-XQXJ-003H | 240x140x100 | 270x170x240 | 3 | 100 | 100 | 1-99 | 0-80 | |
ARS-XQXJ-006H | 300x155x150 | 330x180x310 | 6 | 150 | 300 | 1-99 | 0-80 | |
ARS-XQXJ-010H | 300x240x150 | 330x270x310 | 9 | 200 | 300 | 1-99 | 0-80 | |
ARS-XQXJ-013H | 355x325x150 | 360x330x310 | 13 | 300 | 400 | 1-99 | 0-80 | |
ARS-XQXJ-020H | 530x325x150 | 550x330x310 | 20 | 400 | 500 | 1-99 | 0-80 | |
ARS-XQXJ-027H | 530x325x200 | 550x330x360 | 27 | 500 | 500 | 1-99 | 0-80 |