converter modbus rtu to tcp, modbus rs485 to ethernet converter
System Feature
- Industrial NXP 32-bit ARM MCU
- 24×7 working, soft and hardware Double watchdog
- Support signal fileter
- Stable reconnection strategy for data transmit
- Automatically or manually update interior clock by sms or NTP or
server
- Configurable action schedule(second, minute, day, week, month)
- Event-based linkage programming, e.g. alarm linkage output
- Easy used GUI configure software for setting up to 100 parameters
- Optional inside lithium battery for power lost alarm and keep 8-20
hours working
DI feature
- Trigger dry contact(NO or NC)
DO(T) feature
- Relay drivable output(drive voltage=power supply voltage, Drive
current≤500mA)
- Remote or local event activate DO on/off/pulse
- Status memory function for power lost
DO(K) feature
- Relay output(NO, contact load: 2A / 125VAC,220VDC)
- DO can be activated by remote or local schedule
- Remain down status when power lost
AI feature
- 4-20mA (option: 0-5V) in, Sampling frequency: 33Hz, 10-bit
precision)
- Convert signal to actual measure value,support adjustment
- Support offset and gain, alarm parameters, upload data setting
- Signal lost alarm
SMS feature
- Can add 10 administrator numbers for alarm and remote control
- Sms alarm when any IO channel triggered or out of preset normal
range
- Customizable sms messages, like alarm, receove, report
- Can send sms command to request any channel status or value
- Control output via sms command
- Sms report any IO channel’s status or value on schedule
- Remote setting via sms commands
- Can query SIM card balance, sms forward
- Sms alar for power lost and recover
Wireless network communication
- Option network: cellular(2g/3g/4g) or Wi-Fi
- Support TCP/IP two-way communication with Max.4 servers(IP or
domain)
- Automatically Upload data when alarm or according to schedule
- Communicate with server by optional Cwt_IO, Modbus TCP, http post
protocol
- Support two-way data transparent transmission with RS485 or RS232
Modbus feature
- Can work as a modbus master to poll salve over RS485
- Can work as a modbus slave to be read/write by master(HMI, SCADA
etc.)
- As modbus to gprs/3g gateway
Company Profile
Wireless Remote Monitoring Solutions
Whatever term you use for Telemetry, whether it's remote
monitoring, M2M, Machine2Machine, Machine2Man or even Man2Machine then CWT wire free telemetry products will serve you well. Our Telemetry Solutions have been designed with the user in mind, so they are cost-efficient, easy to configure and install.
We can interface to machines in different ways, whether it be via process signals, or serial
communications, including Modbus.
Benefits of Telemetry
This ‘Internet of Things’ telemetry technology offers rapid
payback, delivering operational, environmental and financial
benefits, from cutting delivery miles, to reacting in good time to
warnings of machinery breakdown, leakage, theft, run-outs and
safety breaches.
Why choose CWT
CWT award-winning Telemetry Solutions are proven globally, in a range of sectors
including chemical & petrochemical, food distribution and
production, transport, water & waste, environmental and factory
automation.
“We were looking for a robust telemetry system and platform to
replace our infield monitoring and critical remote alarm equipment.
We picked Powelectrics as our preferred supplier and Metron View as
our new solution to replace all our infield remote monitoring and
alarm systems. Working with the Powelectrics Team is a real breath
of fresh air, they listen to our needs, help us with our challenges
and provide a really robust solution. They are flexible and
understanding – we are quite demanding! We wouldn’t hesitate to
recommend them and their solutions – a great company to partner
with for our critical system needs.” Technical Manager