Add to Cart
Home grounding wire lightning rod, high-rise building discharge rod, household roof lightning protection.
Working principle of product
In the thunderstorm, the lightning rod and the top of the tall
building are induced by a large amount of charge when there is a
charged cloud over a high building. Because the needle of the
lightning rod is sharp, the most charge is always gathered at the
tip of the conductor when the electrostatic induction is induced.
In this way, the lightning rod congregates most of the charge. The
lightning rod also forms a capacitor with the charged clouds, which
is relatively small because the two pole of the capacitor is small
and the capacitance is very small, that is to say, it can hold very
little charge. When it charges more clouds, the air between the
lightning rod and the cloud layer can easily be breakdown and
become conductor. In this way, the charged cloud layer and the
lightning rod form the path, and the lightning rod is grounded, the
lightning rod can import the charge on the cloud layer into the
earth, so that it does not pose a danger to the high-rise building
and ensures its safety.
Product features
1. beautiful appearance and no rust, strong antioxidant capacity
2. fine welding, good quality, small deformation and good crack
resistance.
3. under the same condition (height), the protection range is
larger than the ordinary lightning rod.
4. free maintenance: passive, no power supply, no energy consuming
components.
Product specification
Model | Specifications | With flange height M | Texture of material | working temperature |
TRSB | 3.1 | 1.2 1.5 1.8 The highest 20m can be done | Stainless steel | -40℃ ~ +80℃ |
3.3 | ||||
4.3 | ||||
5.3 | ||||
6.3 |
Brief introduction
Lightning rod products are used to protect power plants,
substations, electrical transmission lines, individual sections and
industrial and civil high-rise buildings. The lightning rod is
directly grounded, and the height of the needle is higher than the
line. In the course of the lightning guide circuit extending to the
ground, due to the influence of the lightning rod distorting the
power plant, the lightning rod will gradually turn and hit the
lightning rod, thus avoiding the development of the lightning first
guiding the protected equipment. It is a rational equipment to
prevent the direct lightning strike.
Use of attention
1. we need to install the base of lightning rod in advance and
install the base seat in advance.
2. the connection between the flanges of the lightning rod and the
top pedestal of the vertical pole is reliably welded.
3. installation and testing of lightning rod should not be carried
out in thunderstorm days.
4. the value of grounding resistance should be in conformity with
the national standard
5. the lightning rod is selected according to the area and height
of the protected building, the riot day of the mine and the
correction coefficient of the geographical environment and the
property of the building, and the height of the pole of the
lightning rod is determined.
Company profile
Thor has been designing new products to meet the RoHS directive
since 2006. Thor’s ongoing commitment to RoHS compliance includes
continuing efforts to reduce the presence of hazardous substances
in the design and manufacture of a growing number of popular
products.
All types and classes of our lightning and surge arresters
20KA~200KA(8/20μS) and 15KA~50KA(10/350μS) are tested and pass all
the requirements based on their class.