

Add to Cart
household short circuit overload protector, small air switch, DZ47 small circuit breaker.
Product description
DZ47 small circuit breaker is the current that can connect, load
and break normal circuit. A mechanical switch electric appliance
that can also be connected, carrying a certain time and subsection
current under the prescribed irregular conditions, is mainly
applicable to AC 50/60Hz, the rated voltage is 230V/400V and below,
the rated current to 63A.
Product features
1. band energy storage mechanism operation, contact close fast
2. installation and use of convenient novice can also be easy to
install
3. core components are strictly screened, stable performance and
reliable operation.
Product specification
Name | TRS-DZ47 | |||
The number of poles | 1P | 2P | 3P | 4P |
Electric current | 10A/16A/20A/25A/32A/40A/50A/63A | |||
Voltage | 230/400V | |||
function | Short circuit / overload / isolation | |||
Product material | PC flame retardancy | |||
Connection mode | Fire line only | |||
Arc extinguishing mode | Vacuum circuit breaker | |||
Authentication | 3C |
Working principle of product
A small circuit breaker is the principle that the bimetal bending
is directed regularly with the increase of temperature. When the
circuit breaker is closed in normal working condition, the internal
bimetallic sheet is heated by a certain current, and the thermal
expansion coefficient of the two bimetalles is different. It is not
enough to release the release mechanism. When the line appears
general overload, when the overload current is reached, the
bimetallic sheet has a larger bending angle and a lever in the
release mechanism, which is enough to push off the release
mechanism, and from the small circuit breaker, it plays the role of
super load protection. The size of the bimetallic strip is
different from that of the small circuit breaker.
Use of attention
1. the insulation resistance between the pole and pole (except the
monopole), the end and the outlet end of the circuit breaker should
be not less than 2M Omega, and the insulation resistance between
the pole and the shell, the pole and the installation rail should
not be less than 5M Omega. If the product is not required, the
product shall not be used and should be exchanged in time with the
supplier.
2. the setting temperature of the series circuit breaker is 30 +5
C. If a number of circuit breakers are loaded into the sealed box
at the same time, the temperature of the box is raised
correspondingly, and the current is 0.8In.
3. the circuit breaker needs to check contacts after the circuit is
short circuited. If the main contact burns seriously or has pits,
it needs to be repaired.
Company profile
Thor is all about protecting against the damaging effects of power
transients. It is our goal and mission to connect our customer
challenges with high-quality, right-priced solutions and products –
completed by unrivaled customer service and technical support.
All types and classes of our lightning and surge arresters 20KA~200KA(8/20μS) and 15KA~50KA(10/350μS) are tested and pass all the requirements based on their class.
Product packaging:Carton packing
Transportation method
2. Trains, ships, aircraft transport