household miniature circuit breaker air breaking electrical short circuit and overload protection circuit breaker DZ47
Working principle of product
A small circuit breaker is the principle that the bimetal bending
is directed regularly with the increase of temperature. When the
circuit breaker is closed in normal working condition, the internal
bimetallic sheet is heated by a certain current, and the thermal
expansion coefficient of the two bimetalles is different. It is not
enough to release the release mechanism. When the line appears
general overload, when the overload current is reached, the
bimetallic sheet has a larger bending angle and a lever in the
release mechanism, which is enough to push off the release
mechanism, and from the small circuit breaker, it plays the role of
super load protection. The size of the bimetallic strip is
different from that of the small circuit breaker.
Product features
1. band energy storage mechanism operation, contact close fast
2. High limiting coefficient
3. advanced production process and beautiful appearance
Product specification
Name | TRS-DZ47 | |||
The number of poles | 1P | 2P | 3P | 4P |
Electric current | 10A/16A/20A/25A/32A/40A/50A/63A | |||
Voltage | 230/400V | |||
function | Short circuit / overload / isolation | |||
Product material | PC flame retardancy | |||
Connection mode | Fire line only | |||
Arc extinguishing mode | Vacuum circuit breaker | |||
Authentication | 3C |
Brief introduction
DZ47 circuit breaker adopts special arc extinguishing and current
limiting system. It can quickly break down the fault current of DC
distribution system and make the differential coordination greatly
improved. The circuit breaker is especially aimed at accidents
between the measuring and holding screen and the split screen in
the power engineering DC system. The circuit breaker has excellent
performance and can avoid the above failure. The differential
coordination characteristics of circuit breakers are the best
products at home and abroad.
Use of attention
1. the circuit breaker needs to check contacts after the circuit is
short circuited. If the main contact burns seriously or has pits,
it needs to be repaired.
2. the circuit breaker is broken due to the failure of the
protection circuit (leakage, overload or short circuit), then the
handle is in the release position (middle position). After finding
out the cause of the failure, the operating handle should be pulled
down (or placed in the "sub" position), and the operation mechanism
can be closed after the operation (please pay attention to the
different meanings of the three positions of the operating handle
of the circuit breaker).
3. if the circuit breaker can't be broken, it means that the
circuit breaker or line is defective. It needs to be overhauled.
Company profile
Zhejiang Thor Electric Co., Ltd is committed to meeting the requirements of the European Union’s Waste Electrical and Electronic Equipment (WEEE) directive. This directive requires producers of electrical and electronic equipment to finance the take-back for re-use or recycling of their products placed on the EU market after 2006