

Add to Cart
Cardiopulmonary Resuscitation Model
The product features a comprehensive upgrade, highlighting the CPR
training operation of the shop function, and can set their own
values, more in line with clinical and teaching practice CPR
operation requirements.
Executive Criteria: American Heart Association (AHA) 2015
International Cardiopulmonary Resuscitation (CPR) &
Cardiovascular Emergency (ECC) Guidelines
Features:
8-inch color display: analog heart beat display, simulated ECG
display, huge chart data statistics, CPR operation animation
display, the use of Chinese characters show.
simulated human anatomical features obvious, feel real, unified
skin color, shape realistic, beautiful appearance.
Simulated vital signs:
In the initial state, the simulated pupil is scattered and the
carotid artery is no.
Simulated vital signs:
In the initial state, the simulated pupil is scattered and the
carotid artery is no.
During the pressing process, the simulated human carotid artery was
pulsating and the beat frequency was consistent with the pressing
frequency.
After successful rescue, the simulated pupil returned to normal,
carotid artery spontaneous beat.
The pupil scaling and carotid pulse can be turned on and off by the
switch.
can be artificial respiration and extracorporeal compression. Can
be standard airway open, airway indicator light.
three modes of operation: can be CPR training, mode assessment and
actual assessment.
Method 1: CPR training, can be pressed and inflated training.
Mode 2: mode assessment, in the set time, according to the 2015
International Cardiopulmonary Resuscitation Standard, the correct
press and blowing the number of 30: 2 ratio, complete 5 cycles.
Method 3: actual assessment, the teacher can set their own
operating time range, operating standards, the number of cycles,
operating frequency, pressing and blowing ratio.
Controller display function:
Electronic monitoring: electronic indicator shows the monitoring of
airway opening and pressing parts. Artificial respiration and chest
compression of the correct number of counts and the number of
errors counted.
voice prompts: training and assessment of the entire Chinese voice
prompts, can turn on and off the voice, adjust the volume.
bar code shows the amount of blowing: the correct blowing volume of
500 ~ 600ml-1000ml:
When the blowing amount is too small, the bar code is yellow.
When the air volume is appropriate, the bar code is green.
When the blowing volume is too large, the bar code is red.
. The tidal volume is too fast or oversized, causing the gas to
enter the stomach indicator light display; digital count display;
error language prompt;
bar code shows the depth of press, the correct pressure of 5-6cm:
When the pressing depth is too small, the bar code is yellow.
When the pressing depth is appropriate, the bar code is green.
When the pressing depth is too large, the bar code is red.
You can set the operation time in seconds.
operating frequency: 2015 standard for at least 100 to 120 / min,
can also set their own value.
Power state: 220V power supply, after the regulator regulator
output power 12V. (Optional lithium battery, suitable for direct
use without external power supply.)
In the case of
RF remote control function:
RF remote control, the teacher can control the CPR through the
remote control to start, stop, pupil changes, with or without
pulse, printer and other functions can also consciously judge,
emergency call, pulse check, check the breathing, clear foreign
matter to record.
Printer Features:
After the operation is finished, the printing operation is
performed.
The transcripts cover the mode of operation, the sense of judgment,
the first aid respiration, the pulse check, the examination of
breathing, the removal of foreign matter, the operating frequency,
the pressing and blowing ratio, the number of cycles, the number of
times of pressing and blowing during each cycle operation, The
number of errors, the reason and number of errors, the reason and
number of errors, the cause of the error, the set time, the
operating time, and the assessment.
Skin, neck skin, chest skin, hair, the use of imported
thermoplastic elastomer mixed plastic material, from stainless
steel mold, injection molding machine from high temperature
injection, with anatomical indications accurate, feel real, uniform
color, shape realistic Beautiful, durable, disinfection and
cleaning is not deformed, easy disassembly and replacement
characteristics, the material to achieve the same level of foreign
countries.
In the case of
Standard configuration:
senior recovery of a body model;
RF remote control,
Advanced display controller one;
luxury hand pull push the body of a hard plastic box;
recovery operation pad one;
a power adapter;
a data line;
barrier mask (50 sheets / box) a box;
can be set four sets of lungs;
Can be made of a skin;
thermal printing paper two volumes;
2015 international latest operating guide CD-ROM 1;
First aid manual 1;
a manual;
warranty card, certificate;
Our Advantage :
1: For all your inquires about us or our products , we will reply
you in detail within 24 hours.
2: We own professional team have professional attitude to recommend
products and services.
3: One year free warranty , after it is still providing after-sales
service .
4: We offer OEM services , Can print your own logo on the products
.
5: We have very experienced engineers , can help you better use our
products .