AC220V 100N Vibration Test Machine For Accelerometer Calibration

Brand Name:LABTONE
Certification:SGS CE / ISTA / ISO
Model Number:ET10
Minimum Order Quantity:1 Set
Delivery Time:45 Working Days
Payment Terms:T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: B1, No.6, Yanhai Road, Chongtou District, Chang'an Town, Dongguan City, Guangdong Province, China
Supplier`s last login times: within 25 hours
Product Details Company Profile
Product Details

Vibration Test Machine For Vibration Meter And Sensor Calibration


Vibration Test Machine Specifications: ET10


Shaker Specifications V10
Max. sine exciting force10Kg.f peak (100N)
Cooling methodNatural cooling
Frequency range4~10000Hz
Resonance frequency9100Hz ±5%Hz
Max. displacement10 mm p-p
Equivalent mass0.3Kg
Max. acceleration35g
Max. load1kg
Mounting screw holes4*M5 mm
Diameter of armatureФ30 mm
Shaker dimensions185 x 100 x 190 mm
Weight4.5kg
Power amplifier PA401
Rated power400 VA
Frequency rangeDC~20k
Max. Voltage/ Current45V/10A
Signal input voltage< 1.5 VRMS
Noise ratio> 90 dB
Total harmonic distortion< 1%
Max. power consumption (230 V)500 VA@230 V
Weight8Kg
Dimension430 x 260 x 84 mm
Power supplyAC220V
Protective functionOver-voltage, over-current, over-temperature, short circuit

Product Application:


Vibration Transducer widely used in measuring the mechanical structure and components of the shock and vibration, to ensure the vibration measurement results with the necessary accuracy and reliability, ensure that all sensors have uniform standards of measurement, according to the national metrological verification regulations, on the vibration sensor to regular calibration; therefore, vibration transducer calibration is a very important work.

The Vibration Transducer Calibration System is composed of vibration controller, shaker, computer, reference transducer and calibrated transducer. The configuration of Vibration Transducer Calibration System is shown in Figure 1-1.



Principles Instruction:

The calibration method of vibration sensor is two kinds of absolute method and relative method. The absolute calibration method is the basic unit and the method to determine the sensitivity of the sensor. This method is more complex, higher requirements for equipment. Compared method, also known as back-to-back method is measured (STD) back to back (UUT) and standard sensors installed together, both of which are under the same excitation amplitude, the electrical output ratio is the ratio of the sensitivity to the two test results compared to those obtained in the sensor's sensitivity to be measured. The key requirement of the comparison method is that the sensitivity of the standard sensor is higher. The method is divided into simple comparison calibration, back-to-back substitution back-to-back comparison calibration two.


Services:

  • Uptime is paramount: We strive to ensure rapid, high-quality service and support
  • Dialogue: We are committed to responding promptly to all customer requests and questions and to keeping customers informed regarding service and support status so they can plan efficiently
  • Skilled team of technicians and engineers: Our staff continuously receives the latest training in order to deliver the best possible service and support
China AC220V 100N Vibration Test Machine For Accelerometer Calibration supplier

AC220V 100N Vibration Test Machine For Accelerometer Calibration

Inquiry Cart 0