Quick Details:


Place of Origin: Shenzhen, China (Mainland)Input Voltage: AC220V
Brand Name: ESTELOutput Voltage: DC48V
Model Number: GPE4890BOutput Current: 90A
Product Name: Telecom Rectifier SystemInput Frequency 45~65Hz
Certification: ISO9001, CE, 3C, FCC, TLCInput Current: 29.7A
Installation Mode: cabinet 19” rackPower Factor: 0.98
Application: outdoor telecom cabinet

Components:

3×30A rectifier module,

1×monitoring module,

power distribution


Payment & Shipping Terms:


Minimum Order Quantity:1 set
Price:negotiation
Payment Terms:L/C, D/A, D/P, , T/T, Western Union
Supply Ability:10,000 sets per month
Delivery Time:7-10 working days
Packaging Details:carton/wooden case

1. Application


(1) Small scale program controlled exchanger

(2) Access network

(3) Transmission equipment

(4) Mobile communication

(5) Satellite communication ground station

(6) Microwave communication


2. Features


(1) Adoption of active power factor compensation technology with factor >0.98

(2) Wide operating range of AC input voltage: 90~280Vac

(3) Operating temperature range:-25°C~+55°C

(4) Zero current/voltage switching tech with high efficiency ≥90%

(5) Perfect battery management, charge&discharge management, battery temperature compensation, low voltage protection, battery capacity test

(6) Hot-swappable

(7) Input over/under voltage protection

(8) Output over voltage protection

(9) Output over current protection

(10) Output short circuit protection

(11) Auto current sharing, parallel operation

(12) Embedded mounted


3. GPE4890B System Configuration


GPE4890B consists of distribution unit, rectifier module (up to 3 sets) and 1 monitoring module. The configuration is optional, as following table:


ConfigurationRectifier ModuleMonitoring ModulePower Distribution
Optional 1GPR4830AGPM48D (Without Ethernet Port)

GPE4890B:

DC Output: 40A×4 (load);

Battery Output: 70A×1 (battery)

Optional 2GPR4810A
Optional 3GPR4815A
Optional 4GPR4820A

4. GPE4890B Operating Principle


Under normal conditions, every parameter of rectifier modules and distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains fault, the system will be powered by the battery. With the battery discharge, the terminal voltage of the battery starts to descend. When the battery voltage is under 42V±0.5V, the monitoring module reports battery under voltage alarm signal and cuts off the load output, then the power system stops working. When the external AC mains recovers, the system will resume to the normal work state. (All above monitoring data are system default values that users can reset).

5. GPE4890B System Properties


Input
ParameterMin.TypicalMax.UnitRemark
Input voltage range90220280Vac
Input frequency455065Hz
Input current29.7A
Power factor0.98

Output
ParameterMin.TypicalMax.UnitRemark
Output voltage range-42-53.5-58Vdc
Output current range090A176~280VAC
045A90~175VAC
Ripple (Vp-p)200mvAt rated input/output, apply 0.1uF film capacitor and 10uF HF electrolyte capacitor, oscilloscope band width of 20MHz.
Output efficiency9092%220Vac input
8385%110Vac input
Regulation±1%
Load regulation±1%
Line regulation±1%

Insulation rating
ParameterMinRemark
Input - output2121Vdc/10mA//1min
Input-chassis2121Vdc/10mA//1min
Output - chassis750Vdc/10mA//1min
Insulation resistanceAt normal atmospheric pressure, relative humidity: 90%, testing voltage: 500vdc, insulation of input-output, input-ground, output-ground shall not be less than 10MΩ

Ambient requirements
ParametersMin.TypicalMax.UnitRemark
Operating temp-25+55°C≥ 55°C, output with derating power
Storage tempStorage temperature-40+80°C
Humidity1090%Relative humidity, no condensing
Atmospheric pressure70106KPa
Altitude03000m
Cooling methodForced cooling with fan

Mechanical specifications
Dimensions (Overall)482.6mm×255mm×86.1mm
Weight(kg) (Overall)

≤11kg (Inclusive of module)

≤5.175kg (Frame + Distribution, exclusive of module)



6. Electric Connection


Chassis connects with external electric through system interface board. As shown in figure below:



Connector Instruction:

  • L,N,PE is power supply three-core AC input port;
  • LOAD(+) is load positive, LOAD(-) is load negative;
  • BAT(+), BAT(-) are battery port

7. Functions of Monitoring Module


ItemRemark
Remote monitoring of the hostThe host can conduct enquiries, settings and control upon the monitoring and realize the remote message, remote sense and remote control.
Rectifier management by monitoring moduleTo send controlling orders or to get data from the rectifier module via RS485 communication.
Battery managementTo manage low voltage, power down, equalizing/float charge, temperature compensation of the battery.
Output management by monitoring moduleTo inspect and control the system
LED indicatorSignal indication
6 way dry contact outputDry contact setting
COM port signal definition
LCD DisplaySet and revise menu
For details, please refer to specifications of “GPM48DI”.

8. Rectifier Module Property


ItemUnitMin.TypicalMax.Remarks
AC input voltageVac90220280
AC input voltage frequencyHz455065Rated load
Input power factor0.98Rated voltage/ rated load
Output voltage rangeVdc-42-54-58
Output currentA030176~290V ac Input
Output voltage regulation±1%
Ripple (Vp-p)mV200With 0.1uF filmy capacitor and 10uF high frequency electrolyte capacitor, oscilloscope band width of 20MHz.
Output powerW01600176-280V Input
W080090-175V Input
Output efficiency%91220V AC Input
%83110V AC Input
Input over-voltage protectionVac285305Tested with 15A, auto recoverable
Input over-voltage recovery set pointVac280Hysteresis not less than 5V.
Input under-voltage protectionVac85Tested with 4A, auto recoverable
Input under-voltage recovery set pointVac90Hysteresis not less than 5V.
Output over-voltage protection set pointV-58.5-59-61.5Lock up
Output current limitingA323334Auto recoverable
Short circuit protectionALong-term short circuit endurable; Hiccup when short circuit detected; Auto recoverable
Thermal protectionAuto recoverable under ambient temperature of 65°C.
For details, please refer to specifications of “GPR4830A1”.

9. Packing and Shipping




Our Delivery Agent

The goods can be shipped by sea, by air, by courier, by land, by train, etc.
Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.

10. Our Contact Information

Mobile Phone: 0086-13752765943
Telephone: 0086-0755 66600941

Email: info@estel.com.cn

lxf.estel@hotmail.com
Skype: fiona.liang10

China Outdoor 19 Rack Enclosure Rectifier System , Base Station Telecom Power System supplier

Outdoor 19 Rack Enclosure Rectifier System , Base Station Telecom Power System

Inquiry Cart 0