Add to Cart
Electrical Power Quality Monitoring Equipment of Office Buildings for Energy Management
Features:
a.) Number of input channels
Max. 24 channels/device (configurable as voltage or current input)
b.) Measured values:
- instantaneous value of voltage
- instantaneous value of current
c.) Calculated values
- RMS voltage
- RMS current
- Apparent power
- Active power
- Reactive power (incl. capacitive/inductive indication)
- Power factor
d.) Averaging period for calculation: 1 min.
e.) Built-in GSM module for realizing GPRS communication using
different protocols (FTP, http, SNMP) with capability of SMS
sending function, special warnings as required and defined by the
customer
f.) Built-in flash memory to prevent data loss (min. 16MB NOR
flash) with microSD support
g.) Large number of configurable alarm possibilities (power cut,
overcurrent, overvoltage, capacitive/ inductive reactive energy is
over the threshold value, etc.) according to the customer’s needs
h.) Upload periods of calculated values to remote server: 10 min. …
24 hrs. (configurable)
i.) All parameters and the firmware can be updated remotely via the
main wireless communication interface (GPRS/WiFi)
j.) Protection
- Voltage measurement overload (1 min.): 1.5 × Vn
- Voltage isolation: 2kV RMS (1 min., 50Hz)
- Pulse overload capability: 1kV (8/20us)
- Thermal protection
- Housing: IP65
Optional functional:
Saving time domain functions of current and voltage (all measured
instantaneous values are stored) in case of power cut or other
alarm events (min. 0.2s /10 period/, max. 5 sec, according to the
sampling frequency and the number of input channels)
Specification:
Item | Parameter | |||||
Channels | A,B,C phase voltage A,B,C phase current | |||||
Measurement Range | Voltage 0~100V ,220V.380V(customized). Current 0~6A | |||||
Frequency Measurement Error | ≤0.01Hz | |||||
Harmonics Error | Class A | Inter-Harmonics Error | Same as harmonics | |||
Voltage Deviation Error | ≤0.2% | |||||
3 Phase Unbalance Error | ≤0.2% | Current Asymmetry Factor | ≤0.2% | |||
Flickering Error | Pst≤5% Plt≤5% | Fluctuating Error | ≤0.5% | |||
Phase Angel Error | ≤0.2º | Power Error | ≤0.5% | |||
Event Wave Recording | 5 cycles before event, 5 cycles after event | |||||
Display | 320×240mm LCD | |||||
Power Supply | AC 220V±20% Frequency 45Hz~55Hz DC 220V±20% | Consumption | ≤10VA | |||
Environment Temperature | -25℃~75℃ | Relative Humidity | 0~90% non-condensing | |||
Size | 252×182×290mm | Weight | 2.5Kg |
Why Choose Us?
1,We have first-class production lion and strict quality management
system.
2,We have professional team to provide comprehensive one-stop
service for you .
3,We can give customers the most competitive price to meet your
budget.
4,We have big production capacity to guarantee fast delivery and
on-time shipment .
FAQ
Q:Why choose you?
A:We have professional team of worers,service and inspection,and we
have our own factory.
Q:Can I get samples?
A:Of course,we provide the small size sample free.
Q:Could you print our company logo on the nameplate and package?
A:Yes,we can
Q:Where is your factory located?How can I visit there?
A:No. 270, Huangjinkou 3rd Village, Hanyang District, Wuhan City,
Hubei Province, China. All our clients,from home or abroad,you are
most welcome to visit us!