Prepaid Three Phase Smart Electric Meter for AMR System with DLMS/COSEM Protocol
1) One device cater to various demand for smart metering
2) Cost saving and scalable setup
3) Time of Use multi-rate for flexible contractual control
4) Easy to install and low inventory
5) Fraud detection
6) Flexible setting for power limit, tariff, repayment policy
7) IP 54 rated
Details:
● Energy Measurement
Total and time-sharing forward active & reactiveenergy measurement
Total and time-sharing reverse active & reactive energymeasurement
Total forward & reverse apparent energy measurement
Save last one to sixteen months energy data
● Max. Demand Measurement
Measure total and time-sharing forward active &reactive maximum demand and time of occurred
Measure total and time-sharing reverse active &reactive maximum demand and time of occurred
Measure total forward & reverse apparent maximumdemand and time of occurred
● Real Time Measurement
Real-time measurement of the phase voltage, current,total active power,
reactive power, apparent power, total power factor, powergrid frequency
● TOU
4tariffs, 100holidays, 14season‐tables, 8time zone‐tables, each table onmaximum 14 time zones
● Event Log
The last 10 records of following events:Power-down,Programing, Cover opening, Terminal cover opening, Reverse power,
PhaseFail.the records include data and time
● Loadprofile
At least 4 loadprofile channels,Recordat least 490days data when time interval is 30 minutes
● Optical port interface
Support IEC62056-21protocol, 1200bps for communication
● RS-485 serial interface
SupportIEC62056(DLMS/COSEM) protocol, 2400bps for communication
● LCD display
Number of digits value field Up to 8
Digit size 6x14.5mm
● Inputs and outputs
Optical test outputs active energy and reactive energy
● Communication modules(optional)
GPRS module:EGSM900/DCS1800 dual-band,support GSM/GPRSphase2/2+ protocol
PLC module: according to Technology Standards of SSC163X ,centerfrequency 270K, FSK modulate technolgy
Main Parameter:
Item | Specification | |
Reference Current | 1.5(6)A 5(40)A 5(60)A 15(60)A 20(100)A | |
Reference Voltage | 3×220V/380V | |
Dimension (mm) | 290×170×85 | |
Working Voltage Range | 0.8Un~1.15Un | |
Maximum Working Voltage | 0.7Un~1.2Un | |
Working Temperature | -25℃~+60℃ | |
Maximum Working Temperature | -40℃~+70℃ | |
Accuracy | Active 1.0 | Reactive 2.0 |
Factory setting subject to nameplate | ||||||||
For 1.5(6)A meter: Active 6400imp/kW·h | ||||||||
Reactive 6400imp/kvar·h | ||||||||
For 5(40)A meter: Active 600imp/kW·h | ||||||||
Reactive 600imp/kvar·h | ||||||||
For 5(60)A /15(60)A meter: Active 400imp/kW·h | ||||||||
Reactive 400imp/kvar·h | ||||||||
For 20(100)Ameter: Active 300imp/kW·h | ||||||||
Reactive 300imp/kvar·h | ||||||||
Pulse Width (80±20)ms |