Industrial Lora Smart Meter 3 Phase Remote ON / OFF Control With Lora Communication

Brand Name:Radarking
Certification:IEC62053-21; IEC62052-11; IEC62056-21
Model Number:DTZY150
Minimum Order Quantity:50
Delivery Time:35days
Payment Terms:Western Union, T/T, L/C, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Wuhan Hubei China
Address: No.270, Huangjinkou 3rd Village, Hanyang District, Wuhan City, Hubei Province, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Three Phase Lora Smart Meter Industrial Use Smart Meter with Lora Communication


Main Parameter:


Light Coupling Pulse:


Constant:


Factory setting subject to nameplate
For 1.5(6)A meter: Active 6400imp/kW·h
Reactive 6400imp/kvar·h
For 5(40)A meter: Active 600imp/kW·h
Reactive 600imp/kvar·h
For 5(60)A /15(60)A meter: Active 400imp/kW·h
Reactive 400imp/kvar·h
For 20(100)Ameter: Active 300imp/kW·h
Reactive 300imp/kvar·h

Calendar Clock:


Clock Error≤0.5 s/d 0℃~+40℃:±2ppm;
-40℃~+85℃: ±3.5ppm
Clock Frequency1Hz
Battery Life10 year
Battery Continuous Working Period≥5 year

ItemSpecification
Reference Voltage3×220V/380V
Working Voltage Range0.8Un~1.15Un
Maximum Working Voltage0.7Un~1.2Un
Reference Current1.5(6)A 5(40)A 5(60)A 15(60)A 20(100)A
AccuracyActive CL 1.0Reactive CL 2.0
Working Temperature-25℃~+60℃
Maximum Working Temperature-40℃~+70℃

Features:

1. Remote ON/OFF Control

2. Metering


For active combination, reactive combination 1 and reactive combination 2 power, the valid range is –799999.99~799999.99, and unit is kWh or kvarh.

Positive/reverse active power, positive/reverse apparent power, reactive power in 1,2,3,4 quadrants and active/reactive power in A, B, C phase which can be measured. It can set tagged words of active/reactive combination, aim at positive/reverse active power and reactive power in 4 quadrants, to restructure active combination, reactive combination 1 and reactive combination 2.

  • All power can be time-share measured by total and max 4 tariffs. (No time-share measurement for power in A, B, C phases)
  • It can storage power data for 12 settlement period.
  • For positive/reverse active power, positive/reverse apparent power, reactive power in 1,2,3,4 quadrants and active/reactive power in A, B, C phases, the valid range is 0~999999.99, and unit is kWh or kvarh

3. Demand Measurement

4. Settlement Function


5. Tariff

  • Public holiday can be set, including date and daily period meter number of each public holiday.
  • Weekend holiday can be set, which controlled by tagged word, daily period meter number can also be set for each weekend holiday.

  • If the same for public holiday and weekend holiday, daily period meter number of public holiday will be used.

  • Automatic changeover of century calendar, time, leap year.

  • If tariff number in the period of daily period is larger than tariffs, or the tariffs is 0, the power in the period reckon in tariff 1.

  • It can set solution for 2 time zones, 2 daily periods and switching time (yy/mm/dd/hh/mm) of both two.1st time zone and daily period solution is default selection, when reach switching time of time zone, it changes to 2nd solution of time zone, and when reach switching time of daily period, it changes to 2nd solution of daily period. Then set switching time again for 2 solutions,when reach switching time of time zone, it changes to 1st solution of time zone, and when reach switching time of daily period, it changes to 1st solution of daily period. Switching time would be clear since changes of time zone solution and daily period solution.
  • Max 4 tariffs. Each time zone solution can set 14 time zones as max, with starting time and meter number of daily period which is used. Each daily period solution can set 8 daily periods as max, 14 periods per day, with starting time and tariff which is used. Minimum interval of periods is 15 mins., and period interval is larger than actual demand cycle valve, can be set over 00:00

6. Meter Clear

7. Demand Clear

8. Event Clear

9. Power Freezing

10. Security Management & User Authorization

11. Warning Function

12. Power Off Meter Reading Function

13. Clock, Time Function

14. Signal Output Function

15. Basic Communiction Function

16. LCD Display Function


Notes:

No device inside can be adjust by user.
When installing and using, there should be tight enough for each connection line, to avoid from any bad connection which would cause heating to damage the meter. Make sure of the right connection of input and output. Please install the meter on local where is dry and ventilated. Don’t put in the place under direct highlight, especial for infrared window. When using infrared communication, it should take more attention to avoid from any disturb from highlight to infrared interface, and please adjust the distance and angel of infrared, to make sure of reliable communication.

China Industrial Lora Smart Meter 3 Phase Remote ON / OFF Control With Lora Communication supplier

Industrial Lora Smart Meter 3 Phase Remote ON / OFF Control With Lora Communication

Inquiry Cart 0