Add to Cart
FGBX Closed-circuit Circulation Fluidizing Dryer
Description
Usually, for the synthetic drugs, they are crystallized in organic
solvents. Meanwhile, they contain a considerable number of organic
solvents. If these solvents are directly discharged into the
atmosphere, they will not only pollute the environment heavily but
also cause energy waste. So, recovering and recycling all kinds of
the solvents from the raw material and drugs when drying the raw
material and drugs of the medicine meets the requirements of
environmental protection as well as the enterprise development. In
the point, to dry the raw material medicine and partial medicine,
choosing the closed-circuit circulation drying system is more
suitable. The system helps to realize a more effective unity of
economic, better environmental and social benefits.
Advantages compared with the traditional drying equipments
Principle
1.Nitrogen filled and oxygen dump
When closing the corresponding pipeline control valve, the system
is in a completely closed state; when open the exhaust air pump,
the oxygen in the system will be pumped out as to let the system
reach a micro-negative pressure state. When the system pressure
gauge shows a certain value, to close the corresponding exhaust
valve as well as the exhaust air pump. At this time, the nitrogen
control valve is opened and nitrogen is filled into the system.
When the oxygen residue in the system is less than the required
value detected by the on-line oxygen detection device, the system
is in a micro-positive pressure state. At this moment, to close the
the nitrogen control valve and enter into the next process.
2.Drying Period
Open the circulation fan and make the material fluidize well; open
the radiator to heat up the system to the required temperature.
Through the nitrogen transferring, the heat brought out the
moisture and the organic solvents in the material as well as a
small amount of micro-powder. In the system, the fine powder is
collected by a dust collector (filtered to 2-5μm). After going
through the condenser, the solvent and organic solvent inside the
air are condensed into the liquid, which is collected by a storage
tank. The nitrogen becomes dry after dehumidified and condensed,
and circulated inside the system by the fan.
3.Nitrogen protection system
The nitrogen protection is mainly controlled by on-line oxygen
detector. When the oxygen content exceeds the required value, the
nitrogen filling device is automatically opened and fill the
nitrogen into the system. When the oxygen content in the system
meets the requirements, the nitrogen filling device is
automatically closed.
4.Overpressure protection system
When the pressure in the system exceeds the set value, the pressure
detection device acts and automatically empties and relieves the
pressure. When the system pressure meets the requirements, close
the automatic exhaust valve, and the system is running normally.
Parameters
Spec Item | FGBX-5 | FGBX-10 | FGBX-30 | FGBX-60 | FGBX- 120 | FGBX- 200 | FGBX- 300 | FGBX- 500 |
Total volume(L) | 11 | 38 | 120 | 340 | 450 | 670 | 1000 | 1700 |
Diameter(mm) | Ø400 | Ø600 | Ø800 | Ø1100 | Ø1300 | Ø1500 | Ø1600 | Ø1800 |
Capacity(kg/batch) | 3~5 | 5~10 | 18~30 | 40~60 | 80~120 | 150~200 | 250~300 | 350~500 |
Air fan power(kW) | 4.0 | 5.5 | 11 | 15 | 18.5 | 30 | 45 | 55 |
Steam pressure(MPa) | 0.2~0.4 | |||||||
Steam consumtion(kg/h) | 15 | 35 | 70 | 120 | 190 | 220 | 330 | 445 |
Compressed air consumption(m3/min) | 0.3 | 0.4 | 0.5 | 0.6 | 0.8 | 1.0 | 1.0 | 1.5 |
Compressed air pressure(MPa) | 0.4~0.6 | |||||||
Nitrogen pressure(MPa) | 0.4~0.6 | |||||||
Nitrogen consumption(m3/min) | 0.15 | 0.20 | 0.25 | 0.30 | 0.35 | 0.40 | 0.50 | 0.70 |
Coolant pressure(MPa) | 0.2~0.4 | |||||||
Coolant consumption(t/h) | 3.5 | 5.5 | 7.5 | 12.5 | 14.5 | 20 | 28 | 40 |
Total volume(L) | FGBX-5 | FGBX-10 | FGBX-30 | FGBX-60 | FGBX- 120 | FGBX- 200 | FGBX- 300 | FGBX- 500 |