Energy Saving Boiler Spare Part Biomass Power Plant Economizer For Boiler

Brand Name:HD BOILER
Certification:ISO9001 , SGS , TUV , ASME , EN
Model Number:Energy saving economizer
Minimum Order Quantity:1 Set / Sets 10tons
Delivery Time:60 days
Payment Terms:Western Union, L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Address: Address: N0.1, Dongli Road, Donglai, Zhangjiagang City, Jiangsu Province, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

China supply boiler spare part economizer for biomass power plant


Product Description


1.Economizers are mechanical devices intended to reduce energy consumption, or to perform useful function such as preheating a fluid.

2.The term economizer is used for other purposes as well. Boiler, power plant, heating, Refrigeration, ventilating, and air conditioning (HVAC) uses are discussed in this article.

3.In simple terms, an economizer is a heat exchanger.

4.The economizer has advanced manufacturing technology, strict production technology, detection means, with high-tech snake-like tube production lines.


Parameter


Name(unit)Specification(mm)
Bare pipe(OD)25-165
Bare pipe(Thickness)2-8
Fin (Thickness)0.6-3.0
Fin (Height)5-30
Fin tube thread pitch5-30
Fin tube length≤12000

*Note:HD BOILER can bespoke special type of economizer according to customer's requirement.


Details


1.Economizers must be sized for the volume of flue gas, its temperature, the maximum pressure drop allowed through the stack, what kind of fuel is used in the boiler, and how much energy needs to be recovered.

2.Economizers designed for natural gas only, would likely plug-up if installed on a coal boiler and would face increased risk of corrosion if installed on an oil-fired boiler.

3.Some units are designed to keep the flue gases above condensation temperature, and others are made of materials that resist the corrosive effect of condensed flue gases.


Application


During boiler operation in typical commercial and industrial applications, approximately 10-20% of the heating value of fuel is expelled with the stack gases to the atmosphere. Stack economizers are designed to recover significant amounts of this stack gas energy loss, thereby vastly improving boiler system efficiency. There are several considerations when selecting an economizer:


1, Gas-side Pressure Drop. Added back-pressure on the boiler stack affects the combustion air fan throughput capability. The economizer and combustion air fan(s) must be sized properly in order to assure a suitable system operation and capacity.

2, Feedwater Temperature. The feedwater to the economizer must be deaerated and the temperature setpoint minimally at 220oF to prevent tube corrosion.

3,Water-side Pressure Drop. Feedwater pumps must be sized to accommodate the economizer pressure drop. Additionally, a continuous modulating feedwater system is required to ensure proper flow rates through the economizer.



Company Introduction

HD Boiler offers a best in class facility,including:

  • Fabrication area of 200,000 square meters
  • 150 Engineers
  • 600 Coded welders
  • 60 Licensed Inspectors (including NDT level-lll instructors)
  • Grade-ALicenses for Design and Manufacture boiler (issued by the State Administration of Quality Supervision and Inspection)
  • ISO 90001:2008 Quality System
  • ASME Certificate of Utility Boiler
  • ASMES’ , ‘U’ and NB stamp authorization

China Energy Saving Boiler Spare Part Biomass Power Plant Economizer For Boiler supplier

Energy Saving Boiler Spare Part Biomass Power Plant Economizer For Boiler

Inquiry Cart 0